Connect the cold wire feeder to the power source

General

The cold wire feeder is connected to the power source using the interconnecting hosepack.
NOTE!
Risk of damage to the wirefeeding hose if it is attached to the hosepack.
Do not attach the wirefeeding hose to the hosepack under any circumstances.
Connect the cold
wire feeder to the
power source
Fitting the equipment incorrectly can cause serious injury and damage.
Do not carry out the steps described here until you have read and completely understood
all the operating instructions.
(9)
(8)
*
**
***
1
2
3
4
5
6
WARNING!
(7)
red
blue
"Wirefeeder end" of interconnecting hosepack
turn the power source mains switch to the "O" position
Attach the interconnecting hosepack strain relief device if hosepack holder provided
Connect LocalNet plug (1) of interconnecting hosepack to LocalNet connection socket
(8)
Tighten union nut on LocalNet plug
Insert welding potential bayonet plug (3) in (-) socket (9)
Turn welding potential bayonet plug to fasten it
(1)
*
**
(6)
(5)
(4)
(2)
(3)
***
23