Fronius Smart Meter

Integrating the
A Fronius Smart Meter is required to operate the Ohmpilot so that the surplus energy
Fronius Smart
can be measured. An inverter with Datamanager 2.0 or higher from V3.8.1-x onwards or
Meter
a Datamanager Box from V3.8.1-x onwards is required to integrate the Fronius Smart
Meter. On the Datamanager, it must be set whether the Fronius Smart Meter is installed
at the feed-in point or in the consumption branch. The setting must be made on the web-
site under the "Meter" tab for the Datamanager.
Further information on the Datamanager can be found in the "Fronius Datamanager 2.0"
Operating Instructions.

Meter position

(1a) Meter position at feed-in point. The power and energy fed in are measured. Con-
sumption is determined on the basis of these values and the system data.
(1b) Meter position in consumption branch. The power and energy consumed are mea-
sured directly. These values and the system data are used to determine the amount of
power and energy fed in.
How to connect
the Smart Meter
to the Datamana-
ger 2.0
74