Operation - Ribimex PRMPP080/17 Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

4.6- Stopping the engine
Please withdraw the throttle switch and leave the engine running for 1~2 minutes at low speed to
cool the engine.
1. Close the throttle lever to slow position (right) and leave the engine running for 1-2 minutes to
cool it down.
2. Close the fuel valve lever to OFF position.
3. Turn the engine switch to OFF position.
In case of emergency:
Please stop the engine immediately
Turn off the switch and the engine stops running completely
4.7- Adjusting the idle speed of the engine
The idle speed of the engine was adjusted in the factory
The user should not attempt to adjust it to avoid any danger.
After the throttle lead is completely released, if the idling speed of the engine is too low or too high,
please contact the qualified service person to adjust it.
4.8- After use
Remove the hose, drain off the water inside the pump and remove the water and impurity substances
inside the hose. Store it in the specified place.
Important! In cold winter, please be sure to drain off the water inside the pump after use. As the
temperature outdoors is below zero centigrade, the water inside the pump will be frozen, which may
damage the pump.
V. OPERATION
This product is a clean water centrifugal pump of single-step single-suction cantilever. Never use it in
the areas where the water is too deep or too shallow or rich in solid impurity substances.
Use this pump only for the clean water and farming water. Never use it for any other water or liquid
such as drinking water, muddy water, sea water, flammable liquid (petrol, kerosene, fuel oil, heavy oil
etc.) chemicals, acid / alkali liquid etc.
This product is for outdoor used only!
VI. MAINTENANCE, STORAGE AND TROUBLESHOOTING
Before any intervention on product, ensure that motor is off. And cooled off.
Ensure that pump is kept away from fire.
6.1- General Product Maintenance
Clean plastic parts with a soft clean cloth.
Do not use aggressive cleansers (solvents or abrasive cleansers), abrasive sponge or sharp objects.
Do not put or immerse product in water or any other liquid.
6.2- Specific Maintenance
6.2.1- Air filter
• Clean air filter after 50h of operation or after 3 months.