V. OPERATION
5.1- Intended use
- JET pump is designed to draw clear water.
- It must be installed in a dry, ventilated place, protected from weather and excessive heat.
- The maximum suction height should not exceed 8 meters.
- Properly installed, your pump will operate with maximum efficiency and will give you complete
satisfaction.
- The pump is designed for routine household uses such as gardening, irrigation systems, increased water
pressure distribution in non-food, pumping water tanks...
- The pump must not be used for operations not described in this manual.
It should not be used in particular for:
- pumping seawater, waste water, water containing solids, sand or abrasive particles in suspension,
water containing corrosive substances in general.
- pumping water having a temperature above 35°C.
- pumping of explosive, flammable or dangerous liquids.
- pumping water intended for human consumption or food liquids.
NOTE:
- This pump is not intended for cleaning and other pool maintenance operations.
- The pump must not be used in outdoor fountains, garden ponds and similar places.
- The pump is not designed for industrial and / or commercial applications (e.g., in public parks, sports
fields ...).

5.2- Operation

- Proceed with the suction and discharge lines connections described in chapter 4 above.
- Press the on / off switch (6).
- The pump turns on and off when you open or close the terminal (e.g. water tap, spray gun...), see
illustrations 1 and 2 below.
- The pump will stop in case of no water supply; see illustrations 3 and 4 below.
To restart the pump, ensure the suction hose is fully immerse in water, proceed with pump priming (if
necessary), then press the On/Off switch.
5.3- Advise for users
IMPORTANT!
- Do not operate the pump without water in the pump body: extended operation of the pump when the
discharge valve is closed, can seriously damage the pump.
- In case of power failure, it is best to unplug the power outlet.
- In case of prolonged non-use, ensure to switch off the power.