Advanced Energy ARTESYN Power Management Controller Manual page 10

For 1ou ocp power supply units
Table of Contents

Advertisement

1OU OCP Power Management Controller (PMC)
SERVICEABILITY
Required Collateral
Include (at minimum) schematics, CAD, block diagrams, I2C diagram, switch and jumper settings, service/repair/assembly/disassembly instructions (if
applicable), LED definitions.
FRU Information
FRU labels include part number and serial number.
Default Static IP Address
The default static IP address should be included on the label. Default static IP address is "192.168.0.120" across all units.
PCB Information
PCBs have silkscreen markings for jumpers, LEDs, and FRUs
LED Information
Power Status LED
One bi-color LED (blue and AMBER (602 to 610 nm) is incorporated into the front face plate of equipment indicating the power-on, power-off &
standby states as follows:
Color
Power Status
Solid Blue
Power-on
Blinking Blue
Power-on
Amber
Attention
Off
Power-off
Management Ethernet Port LED
Two separate blue LEDs are incorporated into the front face plate of equipment for the management Ethernet port to indicate activity and speed
as follows:
LED
LED Location
Activity LED
Left side of connector
Speed LED
Right side of connector
Programmable Updates
Non-disruptive (no reboot required) update capability is desired where possible for all programmable devices. Where this is not possible it must
be possible to do the bulk of the update (download/write) while still running and reboot into the new firmware.
Utilities are provided with the capability to up and down-rev each article of firmware in the equipment. For the PMC this includes:
All SPI flash devices
eMMC storage
Update is preferred via the Ethernet Redfish interface but should also be possible via the Ethernet and debug command lines.
Cold Aisle Repairs
PMC should be serviced from the cold aisle.
Additional Service Requirements
Additional equirements might be added based on Safety and Data Center requirements. Contact specification owner for latest requirements.
10 advancedenergy.com
Description
All of the power rails are good.
PoE source, no shelf source.
A fault has occurred.
Power is off.
Color
Solid Blue
Blinking Blue
Solid Amber
Description
Link established
Transmitting
1 GBPS

Advertisement

Table of Contents
loading

Table of Contents