„ Confirm laser output (Daily inspection)
Confirm the laser output regularly in order to maintain consistent marking quality.
The laser output should be measured with a commercially available meter using the following steps.
1.
Prepare a commercially available power meter.
• Be sure to use the calibrated power meter.
• The power meter with the detector having the damage threshold (maximum average power density) of more than 10kW/cm
should be used.
• Also the size of the detector should be more than φ10 mm.
• A difference may arise under the high/low temperature. Measuring power with normal temperature (20 to 30 Celsius
degree) is recommended.
• Before measuring the laser power, make sure there is no contamination in the laser emission port. If the laser emission
port is contaminated or damaged, an error may result in the measurement of the laser power.
2.
Install the power meter.
Put the detector of the laser power meter vertically down from the center of the laser emission port and place it at the
following distance, i.e. one-third to half of the specified work distance of the laser marker.
Laser marker model
LP-RH300S / LP-RH300T
LP-RH200S / LP-RH200T
LP-RH100S / LP-RH100T
LP-RH301S / LP-RH301T
LP-RH101S / LP-RH101T
LP-RH305S / LP-RH305T
* The values represent the recommended values for the case where the damage threshold (maximum average power
density) of the detector of power meter is 10kW/cm
Installation distance for
detector of power meter
Work distance
(at base position)
• Do not install the power meter within the focal length of the laser marker. This may cause destruction of the power meter.
Installation distance for
detector of power meter *
90mm
50mm
130mm
2
.
ME-LPRH-SM-3
Laser marker head
Detector of power meter
Laser beam
Workpiece
2
187