Dmx Connection; Connection Of The Control Signal: Dmx Line; Instructions For A Reliable Dmx Connection; Connection Daisy Chain Of The Dmx Line - ProLights ARCSPOT XS VW User Manual

Ip66 spot featuring 800 lumen with 3x 4w variable white source, 10 native
Table of Contents

Advertisement

7 - DMX CONNECTION

CONNECTION OF THE CONTROL SIGNAL: DMX LINE

The product has connectors for DMX input and output.
The default pin-out on both connectors is as the following diagram:
DMX - INPUT
IP67 CONNECTOR
Yellow
Red

INSTRUCTIONS FOR A RELIABLE DMX CONNECTION

Use shielded twisted-pair cable designed for RS-485 devices: standard microphone cable cannot trans-
mit control data reliably over long runs. 24 AWG cable is suitable for runs up to 300 meters (1000 ft).
Heavier gauge cable and/or an amplifier is recommended for longer runs.
To split the data link into branches, use splitter-amplifiers in the connection line.
Do not overload the link. Up to 32 devices may be connected on a serial link.
NOTE: To connect the unit to your DMX network, it is necessary to use the adapters XLR 5 pin-
IP67 signal connector, supplied with this product.

CONNECTION DAISY CHAIN OF THE DMX LINE

Connect the DMX data output from the DMX source to the product DMX input (male connector).
Run the data link from the product DMX output (female connector) connector to the DMX input of the
next fixture.
Terminate the data link by connecting a 120 Ohm signal termination.
The termination is prepared by 120Ω 1/4 W resistor between pins 2 and 3 of the male DMX connector.
Install a DMX termination plug on the last fixture on the link. If a splitter is used, terminate each branch
of the link.
NOTE: when not using the DMX input or DMX output connectors, you must seal the cable ends
with the supplied caps.
Black
White
PROLIGHTS - ArcSpot XSVW
DMX - OUTPUT
IP67 CONNECTOR
Black
White
Yellow
Red
Fig. 06
09