  • Page 1 120856EN-02 2024-01 WIFI Roomie One WiFi V2 Roomie Dual WiFi V2 ART.NO. 120877, 120878, 120879, 120880 ASSEMBLY AND OPERATION INSTRUCTIONS Heat recovery single-room reversible ventilation unit...
  • Page 2 R O O M I E W I F I...
  • Page 3: Table Of Contents

    Contents Purpose ....................6 Delivery set....................6 Technical data ..................7 Design and functioning ................. 9 Mounting and set-up ................13 Maintenance ..................25 Troubleshooting ................... 27 Storage and transportation regulations ..........28 Complaints .................... 29 Waste handling ..................29 R O O M I E W I F I...
  • Page 4 R O O M I E W I F I SAFETY REQUIREMENTS • Read the user’s manual carefully prior to • Transported air must not contain any installing and operating the unit. dust or other solid impurities, sticky • All user’s manual requirements as well as the provisions of all the applicable local •...
  • Page 5 This user’s manual is a main operating document intended for technical, maintenance, and operating The manual contains information about purpose, technical details, operating principle, design, and and should be able to work in accordance with workplace safety rules as well as construction norms and standards applicable in the territory of the country.
  • Page 6: Purpose

    R O O M I E W I F I Purpose The unit is designed to ensure continuous mechanical air exchange for singel rooms in houses, apartments and commercial buildings. The units are designed for indoor use. The unit is equipped with a ceramic regenerator that extract air heat energy regeneration.
  • Page 7: Technical Data

    Technical data The temperature in the room where the indoor unit of the Due to on going developments some models can deviate from what is being described in this manual buildup). If the conditions for using the ventilator are ventilator. Provide fresh air supply through windows.
  • Page 8 R O O M I E W I F I Dimensjoner L = Cartridge with heat exchanger. This determines the Air duct length [mm] minimum length of the duct and varies between the Roomie One WiFi Roomie Dual WiFi the installation instructions for the outer hood. This varies Roomie One WiFi Roomie Dual WiFi Overall dimensions of the indoor assembly unit...
  • Page 9: Design And Functioning

    Design and functioning Roomie Dual WiFi Roomie One WiFi The ventilator consists of a wall duct with a heat recovery The ventilator consists of an indoor unit with a material. It has a decorative indoor unit with air shutters and an outer hood in aluminium. The air shutters in the indoor part is closed when the of dust and foreign objects into the cartridge.
  • Page 10 R O O M I E W I F I Cartridge design Roomie One WiFi Roomie Dual WiFi Filter Filter Regenerator Provides extract air energy regeneration for warming up of Socket connector Provides connection to the Roomie One WiFi has a cartridge with heat exchanger, and fan unit.
  • Page 11 Roomie One WiFi operation modes Ventilation - the ventilator runs either in air exhaust Cycle I. Warm stale air is extracted from the room. As it mode or air supply mode at a set speed. as the ceramic regenerator gets warmed the unit is In this mode some of the ventilators in the network run switched to supply mode.
  • Page 12 • set the duration of the third speed timer (”Party mode”) (4 hours by default). If necessary, in the ”Schedule of the Flexit Fans mobile For the weekly schedule to work correctly, you must set the current date and time correctly in the ”Date and time”...
  • Page 13: Mounting And Set-Up

    Mounting and set-up Read the user´ s manual prior to mounting the unit. Do not block the air duct of the installed unit with dust accumulating materials, such as curtains, cloth shutters, etc. as it prevents air circulation in the room. the front panel, you must ensure that the rod for the damper is in the lowest position and that the...
  • Page 14 R O O M I E W I F I 3. Stick the supplied cardboard template on the and drill holes to a required depth. inner wall using a sticker. For concealed electrical installation, lead the power Use a builder’s level for horizontal alignment of the cable through the marked opening in the mounting mounting template.
  • Page 15 6. Insert the cartridge in the air duct as shown below. Be sure the pointer is directed The pointer must be directed upwards with the retaining clip and connect the connector to the control board. Lay the cables under the clamp and connect the socket connector 7.
  • Page 16 R O O M I E W I F I Changing the cable inlet. It is possible to change the Roomie Dual WiFi cable inlet from underneath the unit to the back. Any connections in the terminal according to the external wiring diagram.
  • Page 17 Ventilation unit set-up DIP switches. You can access the DIP switches by removing the front part of the internal part and lifting up the rubber cover. DIP switch and USB socket under the cover Positioning of the dip switch Roomie One Roomie Dual R O O M I E W I F I...
  • Page 18 The ventilation unit may be operated with the following controls: - infra-red remote controller; - control buttons located on the side wall of the indoor - The application ”Flexit Fans” from a mobile device (smartphone or tablet). Buttons on Remote control...
  • Page 19 Operation of the ventilation unit with the buttons on the indoor unit The speed selection sequence is as follows: I-II-III-Standby. All the units integrated in a single network operate according to the speed settings of the Master unit. I: permanent glowing of the lamp indicator indicates operation of the unit with low speed. Blinking of the lamp indicates activation of the Night mode timer.
  • Page 20 R O O M I E W I F I Remote control of the ventilation unit ON/Standby. The Standby mode depends on the position of the DIP switch 2 (see section DIP switch positions). Speed selection: high-medium-low respectively. Regeneration mode. Roomie One WiFi mode.
  • Page 21 Ventilation unit operation with the mobile application To enable operation of the unit with a mobile device, install the Flexit Fans application to your mobile device. Flexit Fans - App Store Flexit Fans Play Market The ventilator works as a WiFi access point named FAN by default: + 16 ID Number characters) stated on the ventilator casing under the front panel.
  • Page 22 R O O M I E W I F I Ventilator wireless connection diagrams Wiring diagram 1 Connection of up to 8 Slave units or mobile devices to the Master unit with its own wireless access point. Master with a Wi-Fi access point Mobile device Slave No.
  • Page 23 * The ventilator works as a WiFi access point named FAN by following the instructions in the Flexit Fans mobile app. default: + 16 ID Number characters) stated on the ventilator casing • Set the Master ventilator to the special setup mode as...
  • Page 24 R O O M I E W I F I Roomie One WiFi Press the front panel to close the air duct. The fan is stopped. The unit functionality is not changed. To open the air duct pull the front panel through the specially designed recessions.
  • Page 25: Maintenance

    Maintenance Maintenance of the ventilator means regular cleaning of the ventilator surfaces of dust and cleaning and Disconnect the unit from power supply before any maintenance To access the basic assembly units follow the steps: operations. on the indoor unit. Roomie Dual WiFi 1.
  • Page 26 It may cause an alarm! 3. Pull the band to remove the cartridge. Roomie One WiFi Roomie Dual WiFi the application on your mobile device, Flexit times a year. Roomie V.2 • Upon elapse of the set time period (factory setting •...
  • Page 27: Troubleshooting

    Even regular technical maintenance may not completely prevent dirt accumulation on the regenerator and the fan. • Clean the regenerator regularly to ensure its high heat • Clean the regenerator with a vacuum cleaner at least once in a year. 4.
  • Page 28: Storage And Transportation Regulations

    R O O M I E W I F I Storage and transportation regulations Store the unit in the manufacturer’s original packing box in a dry closed ventilated premise with temperature Storage environment must not contain aggressive vapours and chemical mixtures provoking corrosion, insulation and sealing deformation.
  • Page 29: Complaints

    Complaints Warranty claims will only be valid if the instructions in the manuals have been followed. This product is covered by warranty in accordance with the current terms of sale, provided that the product is used correctly and properly maintained. The warranty may be rendered invalid if the system is used incorrectly or maintenance is grossly neglected.
  • Page 30 R O O M I E W I F I...
  • Page 31 R O O M I E W I F I...
  • Page 32 Flexit AS, Moseveien 8, N-1870 Ørje www.flexit.com...