FLOOR PROTECTOR CLEARANCE FROM COMBUSTIBLES FLUE CLEARANCES DIAGRAM STANDARD TRIPLE SKIN FLUE KIT INSULATED ROOM SEAL FLUE KIT INSULATED ROOM SEAL FLUE KIT INSULATED ROOM SEAL FLUE KIT COMPLIANCE DATA HAVEN DIMENSIONS HAVEN PARTS LIST GUARANTEE Ref.Haven Australia v2 11.2023...
SERVICING Stove should be serviced by a professional at least once a year. LIGHTING AND CONTROLLING THE FIRE Rotate the tool clockwise. (into position 1) Suitable fuels for your Charnwood: Wood logs Unsuitable fuels: Petroleum coke Rotate the tool anti-clockwise.
OPERATING INSTRUCTIONS ® Congratulations on becoming the owner of a Charnwood Haven PETROLEUM COKE IS NOT SUITABLE FOR USE ON THIS Stove. Your stove has been approved in smoke controlled areas to APPLIANCE. ITS USE WILL INVALIDATE THE GUARANTEE. burn wood logs if it is used in accordance with these instructions. It This stove is not designed to burn household waste.
Charnwood. The rate of burning and hence the output is controlled by the air The Charnwood Haven is fitted with an air control stop for use in a control (see Fig.1) smoke control area.
(this will help to reduce tar deposits in the may be purchased from your supplier or, in case of difficulty, from chimney). Some experimentation may be necessary to find the Charnwood. setting most suitable for the type of fuel being used and the draw on the chimney.
It is necessary to let the fire out and for the stove to be cold to carry out these operations. The Haven throat plate is one brick. To remove the throat plate, gently lift the right side and slide it to the right so it clears the left brick then rotate the left side down and lower the brick onto the grate.
OPERATING INSTRUCTIONS ® door by unscrewing the 2 x countersunk Allen screws, then by using kept clean in most situations: a brush or a vacuum cleaner, clean out all accessible areas. Once all areas are thoroughly cleaned, replace the flue gas diverter ensuring a) Wet or unseasoned wood, or logs overhanging the front fence will the ‘R’...
If you need further help with your Charnwood then your Installer will be able to provide the answers to most questions. Your Local Charnwood Dealer has a great deal of experience and will also be able to provide helpful advice. Further help is available from Pivot...
(e.g. load distributing plate.) CONNECTIONS TO FLUES The Haven must be connected to the flue using flue pipe of 125mm (5”) diameter. Fig. 6 Horizontal Register Plate With Rear Flue Connection There are several ways of connecting the stove to the flue.
FLOOR PROTECTOR ® MINIMUM FLOOR PROTECTOR DIMENSIONS FOR HAVEN AUSTRALIA MIN. FLOOR PROTECTOR DIMENSIONS 915mm 1145mm (Stove placed centrally) 300mm (in front of the appliance fire door) NON-COMBUSTIBLE FLOOR PROTECTOR MATERIAL Minimum thickness: 6mm Minimum thermal resistivity: 0.026 K/W (compressed board)
CLEARANCE FROM COMBUSTIBLES ® COMBUSTIBLE WALLS PARALLEL POSITION CORNER POSITION Standard Clearance Corner Clearance 186mm 388mm 90mm* 175mm 698mm 325mm * This distance is taken from the back of the VRFA Heat shield to the combustible wall. DB083 (VRFA HEAT SHIELD)
FLUE CLEARANCES DIAGRAM ® Summary of minimum height of flue sytem exit requirements from AS/NZS 2918:2018 6000 3000 More than 3000 or less 600 min. 3000 1000 min. if clear within 3000 of flue top Increase as necessary until nothing within 6000 of flue top Any nearby structure More than 3000 3000...
INSULATED ROOM SEAL FLUE KIT ® REAR FLUE KIT Cowl Room sealed flue (with locking band) 1000 Gutter Wall Penetration min 25 Adjustable wall bracket Wall Plate Cleaning access Wall plate gal NOTE: 2700 There needs to be 50mm clearance to any timber above the flue pipe and a 25mm clearance to any timber to the side and underneath.
Charnwood Haven Australia Parts List HAVEN PARTS LIST Issue ® Item Part No. Description Item Part No. Description 008/DB136 Cook Plate Seal 008/DB071 Door Insulation 008/DB005 Fire Door Seal 004/DB070 Door Back 008/FW29 Door Seal Adhesive 008/DB073 Thermometer Gasket 008/DB072...
• The following conditions apply: • If any part fails due to manufacturing or material defect within the guarantee period Charnwood will, free of charge, either repair or replace the part at their discretion. The decision of Charnwood is final.
Need help?
Do you have a question about the HAVEN and is the answer not in the manual?
Questions and answers