Charnwood ISLAND IIIB Operating & Installation Instructions Manual

Charnwood ISLAND IIIB Operating & Installation Instructions Manual

Advertisement

Quick Links

®
charnwood
I S L A N D
Operating & Installation Instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ISLAND IIIB and is the answer not in the manual?

Questions and answers

Summary of Contents for Charnwood ISLAND IIIB

  • Page 1 ® charnwood I S L A N D Operating & Installation Instructions...
  • Page 3: Table Of Contents

    I S L A N D C O N T E N T S O P E R AT I N G I N S T R U C T I O N S Fuel Door Operation Multi Grate Lighting Controlling The Fire Riddling Refuelling...
  • Page 4: Operating Instructions

    MULTI GRATE correctly and that the chimney has been swept, is sound and free Your Charnwood Island is fitted with a multi grate to enable wood to from any obstructions. The stove is not suitable for use in a shared be burned and ash to be cleared.
  • Page 5: Controlling The Fire

    Thermostat To make ash removal easier there is a special Charnwood ash carrier Knob Thermostat Box available. This may be purchased from your supplier or, in case of difficulty, from ourselves.
  • Page 6: Overnight Burning

    If there are signs of a build up of painting become necessary then special high temperature paints are soot or fly-ash deposits then the fire must be let out in order to clean available from your supplier or from Charnwood. the throat plate and flueways. Cleaning the Glass...
  • Page 7: Chimney Sweeping

    OPERATING INSTRUCTIONS I S L A N D ® Fig. 4. Throat Plate Check that: a) the air inlet at the rear of the stove is not obstructed in any way, b) chimneys and flueways are clear, c) that a suitable fuel is being used, d) that there is an adequate air supply into the room, e) that an extractor fan is not fitted in the same room as the stove.
  • Page 8: If You Need Any Further Help

    Installer will be able to provide the answers to most questions. Your d) Door seals and air control flap pads are intact. Local Charnwood Premier Dealer has a great deal of experience and Over-Firing will also be able to provide helpful advice. Further help is available...
  • Page 9: Installation Instructions

    SPECIFICATION If it is found that there is excessive draw in the chimney then a draught stabilizer should be fitted. Island IIIB It is important that there is sufficient draw in the chimney and that Nominal Heat Output 18kw (61,420 Btu/h) the chimney does not suffer from down-draught.
  • Page 10: Central Heating System

    INSTALLATION INSTRUCTIONS I S L A N D ® Fig. 5. Typical Central Heating & Hot Water System that the hearth must extend in front of the stove by at least 300mm Using 4 Boiler Tappings (12 inches) and to the sides of the stove by at least 150mm (6 inches).
  • Page 11: System Controls

    INSTALLATION INSTRUCTIONS I S L A N D ® Fig. 8. Vertical Register Plate With Bricked Up Fireplace Fig. 11. Horizontal Register Plate With Optional Vertical Rear Flue Connector Soot Door Alternative In Side or Rear Soot Door Positions...
  • Page 12: Connection To Flues

    INSTALLATION INSTRUCTIONS I S L A N D ® With the control knob at the minimum setting the flap should be just domestic hot water. These thermostats are available from ourselves if closed as shown in Fig. 13. To adjust the distance slacken the locking you are unable to obtain them locally.
  • Page 13: Dimensions

    ISLAND IIIB DIMENSIONS I S L A N D ® Flue Outlet To Suit 175mm (7”) Flue Pipe...
  • Page 14: Parts Lists

    No. and Description. In case of difficulty contact the manufacturer at the address shown. This drawing is for identification purposes only. charnwood charnwood BISHOPS WAY, NEWPORT, ISLE OF WIGHT PO30 5WS, UNITED KINGDOM T:+4 4 (0)1983 537799 • F:+4 4 (0)1983 537788 • SPARES@CHARNWOOD.COM • WWW.CHARNWOOD.COM ®...
  • Page 15: Certification

    A.J WELLS & SONS LTD A.J WELLS & SONS LTD Bishops Way, Newport, Isle of Wight PO30 5WS, United Kingdom A Division of A.J.Wells & Sons Limited Registered in England No. 03809371 EN13240:2001 I S L A N D ROOMHEATERS & BOILER FIRED BY WOOD FUEL EC certificate of DS50-CPD-2007 conformity no:...
  • Page 16 BISHOPS WAY, NEWPORT, ISLE OF WIGHT PO30 5WS, UNITED KINGDOM T:+44 (0)1983 537777 • F:+44 (0)1983 537788 • CHARNWOOD@AJWELLS.CO.UK • WWW.CHARNWOOD.COM ® A D i v i s i o n o f A . J . W e l l s & S o n s L i m i t e d R e g i s t e r e d i n E n g l a n d N o . 0 3 8 0 9 3 7 1...