    CONNECTIONS TO FLUES SOOT DOORS PRE LIGHTING CHECK COMMISSIONING CAA AND SMOKE CONTROL COOKING PLATE CRANMORE 3 DIMENSIONS CRANMORE 5 DIMENSIONS CRANMORE 7 DIMENSIONS CRANMORE 3 PARTS LIST CRANMORE 5 PARTS LIST CRANMORE 7 PARTS LIST CERTIFIC ATION Ref.Cranmore v2 03.2022...
  • Page 4: Quick Guide

    High Output Output SERVICING Stove should be serviced by a professional at least once a year. LIGHTING AND CONTROLLING THE FIRE Suitable fuels for your Charnwood: Wood logs Unsuitable fuels: Petroleum coke Liquid fuel Household waste Coal singles Add kindling and paper or...
  • Page 5: Operating Instructions

    Approximate suitable log sizes are: Stove. Your stove has been approved in smoke control areas to burn 244mm(10in) long and 75mm (3in) diameter - Cranmore 3 wood logs if it is used in accordance with these instructions. It is very...
  • Page 6: Refuelling

    Charnwood. Before removing ash ensure that it has cooled down. The ashpan The Charnwood Cranmore 3, Cranmore 5 and Cranmore 7 is fitted slides out for easy ash removal. with an air control stop for use in a smoke control area. This stops the stove from burning too slowly.
  • Page 7: Throat Plate And Flueway Cleaning

    The recommended that the chimney be swept a second time within a Cranmore 3 & 5 throat plate is one brick. month of regular use after installation. To remove the throat plate, if made up of two pieces, first carefully The chimney should be swept at least twice a year.
  • Page 8: Trouble Shooting

    OPERATING INSTRUCTIONS ® door. After sweeping the chimney the appliance flue outlet and the If blackening of the glass still occurs check that all flue connections flue pipe connecting the stove to the chimney must be cleaned with and the blanking plate are well sealed. It is also important that the a flue brush.
  • Page 9: Co Alarm

    “Warning Note” above. IF YOU NEED FURTHER HELP If you need further help with your Charnwood then your Installer will be able to provide the answers to most questions. Your Local Charnwood Premier Dealer has a great deal of experience and will also be able to provide helpful advice.
  • Page 10: Installation Instructions

    The stove arrives bolted and strapped to its pallet. There must be External air supply kits are available please contact Charnwood for adequate facilities for unloading and manoeuvring into position. The more information. Instruction sheet ref: TIS 120...
  • Page 11: Hearth And Fire Surround

    150mm (6 in.). When the fire door is open, it extends used then the chimney may be swept through the appliance. beyond the flat front of the stove by 346mm - Cranmore 3, 430mm - Cranmore 5, and 497mm Cranmore - 7.
  • Page 12: Soot Doors

    If a Vertical Rear Flue adapter is used on the Cranmore 3 then the 010/AA081 spacer plate is required, this is supplied with the Cranmore 3. For top outlet installations, the blanking plate must be removed, have the webbing fitted to its sealing face, and fitted to the rear flue outlet.
  • Page 13: Caa And Smoke Control

    010/BP150S - 6 inch kit used on the Cranmore 5 and Cranmore 7 Reform (Scotland) Act 2014. 010/AP150S - 5 inch kit used on the Cranmore 3 In Northern Ireland appliances are exempted by publication on The kit comprises of a cooking plate and four trivets and can only be a list by the Department of Agriculture, Environment and Rural fitted to the stove if a rear flue connection is made.
  • Page 14: Cranmore 3 Dimensions

    CRANMORE 3 DIMENSIONS ® VERTICAL REAR FLUE ADAPTOR PLAN VIEW To suit 125mm (5”) flue pipe FRONT SIDE REAR...
  • Page 15: Cranmore 5 Dimensions

    CRANMORE 5 DIMENSIONS ® VERTICAL REAR FLUE ADAPTOR PLAN VIEW To suit 150mm (6”) flue pipe FRONT SIDE REAR...
  • Page 16: Cranmore 7 Dimensions

    CRANMORE 7 DIMENSIONS ® VERTICAL REAR FLUE ADAPTOR PLAN VIEW To suit 150mm (6”) flue pipe FRONT SIDE REAR...
  • Page 17: Cranmore 3 Parts List

    CRANMORE 3 PARTS LIST Charnwood Cranmore 3 Parts List ® Issue a Item Part No. Description Item Part No. Description 008/LE035 Door Seal (Inc Adhesive) 004/AA115 Slider 008/FW29 Door Seal Adhesive 004/BR015 Clicker Retainer Plate 006/PV19 Glass (Inc Seal) 008/ES36/01...
  • Page 18: Cranmore 5 Parts List

    Charnwood Cranmore 5 Parts List CRANMORE 5 PARTS LIST Issue C ® Item Part No. Description Item Part No. Description 008/AB035 Door Seal (Inc Adhesive) 008/LC045 Air Control Cover Gasket 008/FW29 Door Seal Adhesive 004/AB115 Slider 006/AB018 Glass (Inc Seal)
  • Page 19: Cranmore 7 Parts List

    Charnwood Cranmore 7 Parts List CRANMORE 7 PARTS LIST Issue D ® Item Part No. Description Item Part No. Description 008/AC035 Door Seal (Inc Adhesive) 008/LC045 Air Control Cover Gasket 008/FW29 Door Seal Adhesive 004/AC115 Slider 006/AC018 Glass (Inc Seal)
  • Page 20: Certific Ation

    Bishops Way, Newport, Isle Of Wight PO30 5WS, United Kingdom A Division of A.J.Wells & Sons Limited Registered In England No. 03809371 CE certificate for compliance with EN13240:2001 EN13240:2001 ROOMHEATERS FIRED BY SOLID FUEL Model: CRANMORE 3 CRANMORE 5 CRANMORE 7 LE11-CPD-2022 LC11-CPD-2019 LD11-CPD-2020...
  • Page 21 ErP (EU 2015/1187) EN - PRODUCT FICHE IT - SCHEDA PRODOTTO FR - FICHE DE PRODUIT PL - KARTA PRODUKTU MANUFACTURER MARQUE MARCHIO Bishops Way, Newport, Isle of Wight PO30 5WS, United Kingdom MARCA A Division of A.J.Wells & Sons Limited Registered in England No. 03809371 MODEL MODÈLE MODELLO...
  • Page 24 your premier dealer...

This manual is also suitable for:

Cranmore 5Cranmore 7

Table of Contents