Page 1
INSTRUCTION MANUAL arlm – 70 antenna radar level meter Read carefully the instructions published in this manual before the first use of the level meter. Keep the manual at a safe place. The manufacturer reserves the right to implement changes without prior notice.
3 . Dimensional drawing ......................... 5 4. Installation and putting into operation ................6 5. M echanical mounting ....................... 6 6. Electrical connection ........................9 7. Examples of ARLM-70 connection.................... 10 7.1 . Wiring diagram of the level meter with current output and PCU unit......10 7 .2 . Wiring diagram of the level meter with current output and PCU unit, MULTI DROP . 10 7 .2 . Wiring diagram of the level meter with current output and PDU unit ......11 7 .2 ...
AfeTy All operations described in this instruction manual have to be carried out only by trained personnel or an accredited person. Warranty and post warranty service must be exclusively carried out by the manufacturer. Improper use, installation or set-up of the level meter can result in crashes in the applica- tion (overfilling of the tank or damage of system components). The manufacturer is not responsible for improper use, losses of work caused by either direct or indirect damage, and for expenses incurred during installation or use of the level meter. 1. B asic description The ARLM-70 „Amanda“ radar level meter works on the FMCW (frequency modulated con- tinuous wave) principle with a frequency of 25 GHz (K-Band). The level meter is equipped with a compact covered funnel antenna. The antenna cover prevents dirt, vapors and gases from entering the antenna. The ARLM-70 is intended for measuring the level of liquid and pasty substances. The level meter is two-wire with a current output of 4 ... 20 mA with HART communication. The measuring range is within 0.3 ... 20 m. 2. r ange of applications Non-contact radar level meters with an antenna are suitable for continuous level measu- rement at medium and longer distances, liquids and pasty substances.. They can be used both in various closed tanks, containers, in semi-open sumps, and in open space. Their use is suitable where their advantages are fully applied:...
. Plus pole (+) is connected to the terminal ( + ), minus pole (-) to the terminal (-) and the shielding (only for shielded cables) to the terminal ( ). Fig. 13: Wiring diagram of the level meter Procedure to connect the cable to the level meter: with current output ARLM-70 _ _-_- I Unscrew the nut of the upper transparent lid. Take the upper edge of the display module and metal display unit connector take it out carefully by mild swinging up. clip If you cannot grasp the module, you can use a small screwdriver. Insert it as far as the seam...
7. e arlm-70 xamples of Ø connection G 2" 7 .1 . Connection diagram of the level meter with the current output to the PCU unit Ø SW 65 7 .2 . Connection diagram of the level meter with the current output to the PCU unit Ø...
Page 28
U Tescomy 249 760 01 Zlín Czech Republic phone: +420 577 002 003 e-mail: sale@dinel.cz www.dinel.cz applies to the firmware version: level meter 1.0 display module 6.0 and higher The manufacturer reserves the right to change the specifications and appearance of the product without prior notice Find the updated version at www.dinel.cz 01/2024 version: 08/2017...