GBC Fusion Punch II with Offset and Bypass Stacker
Floor Load
Device
Fusion Punch II
Bypass Stacker
Offset Stacker
Floor Level
Configuration
X1
X2
Uniform load
51.67 lbs / sq.ft. (253 kg / sq. m)
53 lbs / sq.ft. (259 kg / sq. m)
45 lbs / sq.ft. (219 kg / sq. m)
Fusion Punch II
Caster
Note: The leveling feet on the Fusion Punch II and the Bypass /
Offset Stackers are only used to lock the solution in place after
installation. The casters will carry the entire load at all times and
therefore there are is no point load for the leveling feet.
X2
Fusion Punch II
Measurement
Specification
9 ft (2.74 m)
2 " (50.8 mm) over entire length, or 0.22 in./ ft (15.2 mm / m)
6.75 ft (2.1 m)
1.48 " (37.6 mm) over entire length, or 0.22 in./ ft (15.2 mm / m)
Note: The floor level is based on a printer paper exit height
above the floor of 34" (860 mm).
1-5
Point load
Casters A: 108.5 lbs / sq.in. (7.63 kg / sq. cm)
Casters B: 201.5 lbs / sq.in. (14.2 kg / sq. cm)
Casters: 80 lbs / sq.in. (5.62 kg / sq. cm)
Casters: 67.5 lbs / sq.in. (4.75 kg / sq. cm)
Bypass
Stacker
Stacker
Feet
X1
Bypass
Stacker
Offset
Offset
Stacker