Installing the Outer Rails on the Rack

Installing the Outer Rails
1. Confirm that the left and right outer rails have been correctly identified.
2. Release the small locking lever on the inside of the middle rail and push the middle rail
back into the outer rail.
3. Insert the pins at the front of the outer rail into the square holes on the front of the rack.
Push until the latch snaps into place.
4. The outer rail is actually two pieces that slide to lengthen. Pull out the rear of the outer
rail, adjusting the length until the square pin assembly passes, then fits against the back
of the rear post. Be careful to keep the rail level.
5. Insert the pins at the rear of the outer rail into the square holes on the rear of the rack.
Push until the latch snaps into place.
6. Repeat for the other outer rail.
Note: Figures are for illustrative purposes only. Your actual chassis may differ. Always install
servers into racks from the bottom up.
Locking Lever on the Middle Rail
Figure 2-4. Installing the Outer Rails
25
Chapter 2: Server Installation