Table of Contents

Advertisement

Quick Links

A+ Server
®
AS -2015CS-TNR
USER'S MANUAL
Revision 1.0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the A+ Server AS-2015CS-TNR and is the answer not in the manual?

Questions and answers

Summary of Contents for Supermicro A+ Server AS-2015CS-TNR

  • Page 1 A+ Server ® AS -2015CS-TNR USER’S MANUAL Revision 1.0...
  • Page 2 State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Supermicro's total liability for all claims will not exceed the price paid for the hardware product.
  • Page 3 If you have any questions, please contact our support team at: support@supermicro.com This manual may be periodically updated without notice. Please check the Supermicro website for possible updates to the manual revision level. Secure Data Deletion A secure data deletion tool designed to fully erase all data from storage devices can be found on our website: https://www.supermicro.com/about/policies/disclaimer.cfm?url=/wdl/utility/...
  • Page 4: Table Of Contents

    Preface Contents Chapter 1 Introduction 1.1 Overview ..........................9 Network Connection Options ....................9 1.2 System Features ........................10 Front View .........................10 Drive Carrier Indicators ....................10 Control Panel .........................11 Rear View ..........................13 Power Supply Indicator ....................14 Top View ..........................15 1.3 System Architecture ......................16 1.4 Motherboard Layout ......................17 Quick Reference Table ......................18 System Block Diagram ......................19...
  • Page 5 Preface Chapter 3 Maintenance and Component Installation 3.1 Removing Power .......................28 3.2 Accessing the System ......................29 3.3 Processor and Heatsink Installation ...................30 3.4 Memory Support and Installation ..................38 Memory Support ........................38 DIMM Module Population Sequence ................39 DIMM Installation ......................40 DIMM Removal .........................40 3.5 Motherboard Battery ......................41 3.6 Storage Drives ........................42 Installing Drives .........................42...
  • Page 6 Preface 4.5 LED Indicators ........................71 Chapter 5 Software 5.1 Microsoft Windows OS Installation ..................73 5.2 Driver Installation ........................75 5.3 SuperDoctor 5 ........................76 ® 5.4 IPMI ............................77 Chapter 6 Optional Components 6.1 Storage Control Cards .......................78 Storage Protocols Supported ..................78 6.2 Upgrade Fans ........................78 6.3 GPU Support ........................79 6.4 Cable Management Arm.....................79 6.5 TPM Security Module ......................81...
  • Page 7 7.9 Where to Get Replacement Components ................95 7.10 Reporting an Issue ......................95 Technical Support Procedures ..................95 Returning Merchandise for Service ...................95 7.11 Feedback ..........................96 7.12 Contacting Supermicro ......................97 Appendix A Standardized Warning Statements for AC Systems Appendix B System Specifications...
  • Page 8 San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) Sales-USA@supermicro.com (Sales Inquiries) Government_Sales-USA@supermicro.com (Gov. Sales Inquiries) support@supermicro.com (Technical Support) RMA@supermicro.com (RMA Support) Webmaster@supermicro.com (Webmaster) Website: www.supermicro.com Europe Address: Super Micro Computer B.V.
  • Page 9: Chapter 1 Introduction

    2U; 17.2” x 3.5” x 25.5” (depth) (43.7 x 8.9 x 64.8 cm) A Quick Reference Guide can be found on the product page of the Supermicro website. The following safety models associated with the AS -2015CS-TNR have been certified as compliant with UL or CSA: LA26CDC-R8H13, LA26CDC-R12H13, LA26-R16H13, LA26CDC- R11DH13, LA26-8, LA26-12,LA26-16, LA26-11D.
  • Page 10: System Features

    Chapter 1: Introduction 1.2 System Features The following views of the system display the main features. Refer to Appendix B for additional specifications. Front View Control Panel Service/Asset Tag with BMC Password Figure 1-1. Front View Logical Storage Drive Numbers Item Description 0 - 11...
  • Page 11: Control Panel

    Chapter 1: Introduction Control Panel Power Button UID Button/LED BMC Reset Power LED HDD LED NIC LED NIC LED Power Fail LED Information LED Figure 1-2. Control Panel Control Panel Features Feature Description The main power switch applies or removes primary power from the power supply to the server Power Button but maintains standby power.
  • Page 12 Chapter 1: Introduction Information LED Color, Status Description Red, solid An overheat condition has occurred. Red, blinking at 1Hz Fan failure, check for an inoperative fan. Power failure, check for a non-operational power Red, blinking at 0.25Hz supply. Red, solid, with Power LED blinking Fault detected green Blue and red, blinking at 10 Hz...
  • Page 13: Rear View

    Chapter 1: Introduction Rear View BMC LAN Port PWS1* 12 13 PWS2* UID LED VGA Port USB Ports COM Port Figure 1-3. System: Rear View System Features: Rear Feature Description Power Supplies Two redundant power supply modules** VGA Port One VGA port USB Ports Two USB 3.0 ports COM Port...
  • Page 14: Power Supply Indicator

    Indicates that the power supply has a warning condition and continues to operate. Indicates that the power supply is plugged in, and is in an abnormal state. The Solid Amber system might need service. Please contact Supermicro technical support. No AC power to modules...
  • Page 15: Top View

    Chapter 1: Introduction Top View Two AIOM Slots Power Supply Modules M.2 Slots Single AMD EPYC™ 9004 Processor 12 DIMM Slots DDR5 System Fans Figure 1-4. System: Top View System Features: Top Feature Description AIOM Slots Two Advanced I/O modules M.2 Slots Two M.2 NVMe Gen3 slots (for boot) Power Supply...
  • Page 16: System Architecture

    Chapter 1: Introduction 1.3 System Architecture This section shows the locations of the system's main components. Riser Card RSC- Riser Card RSC- D2-666G5 D2R-666G5 Motherboard H13SSW Storage Backplane BPN-NVME5-LB16A-S12 Figure 1-5. Main Component Locations...
  • Page 17: Motherboard Layout

    Chapter 1: Introduction 1.4 Motherboard Layout Below is a layout of the H13SSW motherboard with jumper, connector and LED locations shown. See the table on the following page for descriptions. For detailed descriptions, pinout information and jumper settings, refer to Chapter 4 or the Motherboard Manual.
  • Page 18: Quick Reference Table

    4-Pin BMC External I C Header (For an IPMI-Supported Card) DIMMA1~DIMML1 DIMM Slots FAN1~FAN6 System Cooling Fans AIOM1~AIOM2 Supermicro® Advanced I/O Module (AIOM) Slots JFP1 Front Control Panel Header 1 LWIO/ RWIO Riser Slots IPMI LAN RJ45 Dedicated IPMI LAN Port...
  • Page 19: System Block Diagram

    Connection MCIO to MCIO cable MCIO to SATA cable Better Faster Greener™ © 2022 Supermicro Subject to change without notice Figure 1-7. Chipset Block Diagram Note: This is a general block diagram and may not exactly represent the features in your...
  • Page 20: Chapter 2 Server Installation

    Chapter 2: Server Installation Chapter 2 Server Installation 2.1 Overview This chapter provides advice and instructions for mounting your system in a server rack. If your system is not already fully integrated with processors, system memory etc., refer to Chapter 3 for details on installing those specific components.
  • Page 21: Rack Precautions

    Chapter 2: Server Installation • This product is not suitable for use with visual display workplace devices according to §2 of the German Ordinance for Work with Visual Display Units. Rack Precautions • Ensure that the leveling jacks on the bottom of the rack are extended to the floor so that the full weight of the rack rests on them.
  • Page 22: Airflow

    Chapter 2: Server Installation Airflow Equipment should be mounted into a rack so that the amount of airflow required for safe operation is not compromised. Mechanical Loading Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading.
  • Page 23: Installing The Rails

    Chapter 2: Server Installation 2.4 Installing the Rails There are a variety of rack units on the market, which may require a slightly different assembly procedure. This rail set fits a rack between 25.6" and 33" deep. The following is a basic guideline for installing the system into a rack with the rack mounting hardware provided.
  • Page 24: Installing The Outer Rails Onto The Rack

    Chapter 2: Server Installation Installing the Outer Rails onto the Rack Each end of the assembled outer rail includes a bracket with square pegs to fit into your rack holes. If you have an older rack with round holes, these brackets must be removed, and you must use screws to secure the rail to the rack.
  • Page 25: Installing The Chassis Into A Rack

    Chapter 2: Server Installation 2.5 Installing the Chassis into a Rack Once rails are attached to the chassis and the rack, you can install the server. 1. Pull the middle rail out of the front of the outer rail and make sure that the ball bearing shuttle is locked at the front of the middle rail.
  • Page 26: Removing The Chassis From The Rack

    Chapter 2: Server Installation Removing the Chassis from the Rack Caution! It is dangerous for a single person to off-load the heavy chassis from the rack without assistance. Be sure to have sufficient assistance supporting the chassis when removing it from the rack.
  • Page 27: Installing The Server Into A Telco Rack

    Chapter 2: Server Installation Installing the Server into a Telco Rack To install the server into a Telco (or “open”) type rack, use L-shaped brackets (p/n MCP-290- 00016-0N) on either side of the chassis (four total). 1. Determine how far the server will extend out from the front of the rack. The chassis should be positioned so that the weight is balanced between front and back.
  • Page 28: Chapter 3 Maintenance And Component Installation

    Chapter 3: Maintenance and Component Installation Chapter 3 Maintenance and Component Installation This chapter provides instructions on installing and replacing main system components. To prevent compatibility issues, only use components that match the specifications and/or part numbers given. Installation or replacement of most components require that power first be removed from the system.
  • Page 29: Accessing The System

    Chapter 3: Maintenance and Component Installation 3.2 Accessing the System The chassis features a removable top cover for access to the internal components. Removing the Top Cover 1. Unscrew the thumbscrew at the rear of the cover and slide the cover toward the rear. 2.
  • Page 30: Processor And Heatsink Installation

    CPU socket cap is in place and none of the socket pins are bent; otherwise, contact your retailer immediately. • Refer to the Supermicro website for updates on CPU support. Installing the Processor and Heatsink 1. Unscrew the screw #1 holding down the force frame.
  • Page 31 Chapter 3: Maintenance and Component Installation 2. The spring-loaded force frame will raise up after the screw securing it (#1) is removed. Gently allow it to lift up to its stopping position. Force Frame 3. Lift the rail frame up by gripping the lift tabs near the front end of the rail frame. While keeping a secure grip of the rail frame, lift it to a position so you can do the next step of removing the external cap.Remove the external cap from the rail frame by pulling it upwards through the rail guides on the rail frame.
  • Page 32 Chapter 3: Maintenance and Component Installation 4. Remove the external cap from the rail frame by pulling it upwards through the rail guides on the rail frame. External Cap 5. The CPU package is shipped from the factory with the carrier frame pre-assembled. Grip the handle of the carrier frame/CPU package assembly from its shipping tray, and while gripping the handle, align the flanges of the carrier frame onto the rails of the rail frame so its pins will be at the bottom when the rail frame is lowered later.
  • Page 33 Chapter 3: Maintenance and Component Installation Note: You can only install the CPU inside the socket in one direction with the handle at the top. Make sure that it is properly inserted into the CPU socket before closing the rail frame plate.
  • Page 34 Chapter 3: Maintenance and Component Installation 8. Gently lower the rail frame down onto the socket until the latches on the rail frame engage with the socket housing and it rests in place. DO NOT force it into place! 9. The force frame is spring loaded and has to be held in place before it is secured. Important: Use a torque screwdriver, set it at 12.5~15.0 kgfcm (10.85~13.01 lbf-in) with a Torx T20 screw head bit, to prevent damage to the CPU.
  • Page 35 Chapter 3: Maintenance and Component Installation 10. Place and re-screw the screw in the middle to the way you removed it. When finished, the force frame will be secure over both the rail frame and CPU package. 11. After the force frame is secured and the CPU package is in place, now you must install the heatsink to the frame.
  • Page 36 Chapter 3: Maintenance and Component Installation 12. Using a diagonal pattern, tighten the six screws down on the heatsink in a clockwise fashion till it is secure. The heatsink will now be secured and you have finished installing the processor and heatsink onto the motherboard. Repeat this procedure for any remaining CPU sockets on the motherboard.
  • Page 37 Chapter 3: Maintenance and Component Installation Un-installing the Processor and Heatsink 1. Remove the heatsink attached to the top of the CPU package by reversing the installation procedure. 2. Clean the thermal grease left by the heatsink on the CPU package lid to limit the risk of it contaminating the CPU package land pads or contacts in the socket housing.
  • Page 38: Memory Support And Installation

    The H13SSW supports up to 3TB of ECC DDR5 4800MT/s speed, RDIMM/LRDIMM/3DS memory in 12 slots. Refer to the table below for additional memory information. Note: Check the Supermicro website for possible updates to memory support. DIMM Population Guide Channel...
  • Page 39: Dimm Module Population Sequence

    Chapter 3: Maintenance and Component Installation DIMM Module Population Sequence There is no specific order or sequence required when installing memory modules. However do keep the following in mind: • Mixed DIMM speeds can be installed. However, all DIMMs will run at the speed of the slowest DIMM.
  • Page 40: Dimm Installation

    Chapter 3: Maintenance and Component Installation DIMM Installation 1. Insert the desired number of DIMMs into the memory slots. See Memory Support for details on memory population guidelines. 2. Push the release tabs outwards on both ends of the DIMM slot to unlock it. Receptive Point 3.
  • Page 41: Motherboard Battery

    Chapter 3: Maintenance and Component Installation 3.5 Motherboard Battery The motherboard uses non-volatile memory to retain system information when system power is removed. This memory is powered by a lithium battery residing on the motherboard. Replacing the Battery Begin by removing power from the system.
  • Page 42: Storage Drives

    These carriers also help promote proper airflow. Each carrier has a small space on the front to receive a label, orange or purple, to help distinguish SAS/SATA/NVMe from other protocols. Note: Enterprise level hard disk drives are recommended for use in Supermicro servers. For compatible storage drives, see the H13SSW motherboard web page.
  • Page 43 Chapter 3: Maintenance and Component Installation Handle Release Button Figure 3-5. Removing a Drive Carrier Installing a Drive 1. Install the drive directly into the tray with four screws underneath. 2. Insert the drive carrier into its bay, keeping the release button on the right. When the carrier reaches the rear of the bay, the release handle will retract.
  • Page 44: Drive

    Chapter 3: Maintenance and Component Installation 3.5" Drive Post Insert this side first Post Figure 3-6. Installing a 3.5" Drive into a Carrier Insert this side second Figure 3-7. Installing a 3.5" Drive into a Carrier...
  • Page 45: Drive

    Chapter 3: Maintenance and Component Installation Installing a 2.5" Drive 1. Install the drive directly into the tray with four screws underneath. 2. Insert the drive carrier into its bay, keeping the release button on the right. When the carrier reaches the rear of the bay, the release handle will retract. 3.
  • Page 46: Installing M.2 Solid State Drives

    Chapter 3: Maintenance and Component Installation Installing M.2 Solid State Drives The motherboard supports two PCIe 3.0 M.2 slots in the M-Key 2280/22110 form factor. Caution: Use industry-standard anti-static equipment, such as gloves or wrist strap, and follow precautions to avoid damage caused by ESD. M.2-C2 M.2-C1 MEGERAC LICENSE...
  • Page 47: System Cooling

    Chapter 3: Maintenance and Component Installation 3.7 System Cooling Fans Three 4-cm fans provide the cooling for the system. Make sure the chassis makes a good seal so the cooling air circulates properly through the chassis. Figure 3-10. Fan Positions Changing a System Fan 1.
  • Page 48: Air Shrouds

    Chapter 3: Maintenance and Component Installation Air Shrouds Air shrouds concentrate airflow to maximize fan efficiency. They do not require screws to install. Installing the Standard Air Shrouds • Position the air shrouds as illustrated in the figure below, sliding the front over the edge of the fan tray.
  • Page 49: Power Supply

    • Solid Amber: When illuminated, indicates that the power supply is plugged in, and is in an abnormal state. The system might need service. Please contact Supermicro technical support. Changing the Power Supply Module: 1. Unplug the AC cord from the module to be replaced.
  • Page 50 Chapter 3: Maintenance and Component Installation PWS1 PWS2 Release Tabs Figure 3-12. Replacing the Power Supply...
  • Page 51: Aiom Cards

    Chapter 3: Maintenance and Component Installation 3.9 AIOM Cards The system supports up to two advanced input/output module (AIOM) network port cards. AIOM Configurations Slot Mechanical Electrical Small Form Factor, OCP 3.0 PCIe 5.0 x16 (NCSI) Small Form Factor, OCP 3.0 PCIe 5.0 x16 Figure 3-13.
  • Page 52 Chapter 3: Maintenance and Component Installation Figure 3-14. Installing AIOMs...
  • Page 53: Pcie Expansion Cards

    Chapter 3: Maintenance and Component Installation 3.10 PCIe Expansion Cards The system accepts six full-height, half-length expansion cards, mounted on riser cards and brackets. Figure 3-15. Expansion Card Slots in the Chassis 12 SATA only or 12 SATA/4NVME Hybrid Expansion Card Slots Slot Description PCIe 5.0 x16 slot (FHFL)
  • Page 54: Sata/12 Nvme Hybrid

    Chapter 3: Maintenance and Component Installation 12 SATA/12 NVMe Hybrid Expansion Card Slots Slot Description PCIe 5.0 x16 slot (FHFL) PCIe 5.0 x16 slot (FHHL) PCIe 5.0 x16 AIOM slot (NCSI) PCIe 5.0 x16 AIOM slot 12 NVME Expansion Card Slots Slot Description PCIe 5.0 x16 slot (FHHL)
  • Page 55 Chapter 3: Maintenance and Component Installation Installing an Expansion Card 1. Power down the system as described in section 3.1 and remove the cover. 2. Pull the riser bracket up and out using the pull-tabs. Riser Bracket Figure 3-16. Riser Card Bracket and Expansion Slots 3.
  • Page 56 Chapter 3: Maintenance and Component Installation 比例 Figure 3-17. Example Expansion Cards...
  • Page 57: Cable Routing

    Chapter 3: Maintenance and Component Installation 3.11 Cable Routing Use this section to route or reroute cables. Proper routing is important to maintain airflow through the system. Cable part numbers and descriptions are available at the Online Cable Matrix. Figure 3-18. Backplane Cable Routing Diagram Backplane BPN-NVME5-LA26A-S12...
  • Page 58: Sata + 4 Pcie X16

    Chapter 3: Maintenance and Component Installation 12x SATA + 4 PCIe x16 12x SATA + 4 PCIe x16 Front cables (Top View – System) Cable Description BPN/Riser and Port MB Port SATA 0-3 CBL-MCIO-1243S4Y JMCIO7 SATA 4-7 CBL-MCIO-1227EQS4 SATA 8-11 JMCIO8 Rear PCIe Cable PCIe x16 (Slot1)
  • Page 59: Sata + 4 Pcie X16 + Optional 2 Pcie X8

    Chapter 3: Maintenance and Component Installation 12x SATA + 4 PCIe x16 + Optional 2 PCIe x8 12x SATA + 4 PCIe x16 + Optional 2 PCIe x8 Front cables (Top View – System) Cable Description BPN/Riser and Port MB Port SATA 0-3 CBL-MCIO-1243S4Y JMCIO7...
  • Page 60: Sata/4X Nvme Hybrid, 4X Pcie X16

    Chapter 3: Maintenance and Component Installation 12x SATA/4x NVMe Hybrid, 4x PCIe x16 12x SATA/4x NVMe Hybrid, 4x PCIe x16 Front cables (Top View – System) BPN/Riser and Cable Description MB Port Port SATA 0-3 JMCIO7 CBL-MCIO-1243S4Y SATA 4-7 CBL-MCIO-1227EQS4 SATA 8-11 JMCIO8 NVMe 0-1...
  • Page 61: Nvme + 2X Pcie X16

    Chapter 3: Maintenance and Component Installation 12 NVMe + 2x PCIe x16 12 NVMe + 2x PCIe x16 Front cables (Top View – System) BPN/Riser Cable Description MB Port and Port CBL-MCIO-1232M5 NVMe 0-1 JMCIO1 NVMe1 CBL-MCIO-1232M5 NVMe 2-3 JMCO2 NVMe2 CBL-MCIO-1232M5 NVMe 4-5...
  • Page 62: Chapter 4 Motherboard Connections

    Chapter 4: Motherboard Connections Chapter 4 Motherboard Connections This section describes the jumpers, connections and LEDs on the motherboard and provides pinout definitions. Some connections might not be used in this system. A motherboard layout indicating component locations may be found in Chapter 1.
  • Page 63: Headers And Connectors

    Port 80 connection. Use this header to enhance system performance and data security. Refer to the table below for pin definitions. Please go to the following link for more information on the TPM: http://www.supermicro.com/manuals/other/TPM.pdf. Trusted Platform Module Header Pin Definitions...
  • Page 64 Chapter 4: Motherboard Connections USB Ports (USB0/1) There are a total of four USB ports supported on the motherboard. Two are located on the front panel, and two are located on the back panel. Front Panel USB 0/1 (2.0) Pin Definitions Pin# Definition Pin#...
  • Page 65 Chapter 4: Motherboard Connections Power SMB Header (PWRI2C) Power System Management Bus (I C) header monitors power supply, fan and system temperatures. See the table below for pin definitions. Power SMB Header Pin Definitions Pin# Definition Clock Data Alert Ground +3.3V 4-pin External BMC I2C Header A System Management Bus header for IPMI 2.0 is located at JIPMB1.
  • Page 66 Chapter 4: Motherboard Connections Control Panel JF1 contains header pins for various control panel connections. See the figure below for the pin locations and definitions of the control panel buttons and LED indicators. All JF1 wires have been bundled into a single cable to simplify this connection. Make sure the red wire plugs into pin 1 as marked on the motherboard.
  • Page 67 Chapter 4: Motherboard Connections NMI Button The non-maskable interrupt button header is located on pins 19 and 20 of JF1. Refer to the table below for pin definitions. NMI Button Pin Definitions (JF1) Pin# Definition NMI Switch Ground Power LED The Power LED connection is located on pins 15 and 16 of JF1.
  • Page 68 Chapter 4: Motherboard Connections UID LED The UID LED is on pins 7 and 8 of JF1. Connect the front panel UID LED to this header to indicate when the rear UID switch is turned on. Refer to the table below for pin definitions. UID LED Pin Definitions (JF1) Pin#...
  • Page 69: Input/Output Ports

    See 2.6 for the front panel UID LED header location on JF1. Note: UID can also be triggered via IPMI on the serverboard. For more information on IPMI, please refer to the IPMI User's Guide posted on our website at http://www.supermicro.com...
  • Page 70: Jumpers

    Chapter 4: Motherboard Connections 4.4 Jumpers Explanation of Jumpers To modify the operation of the motherboard, jumpers are used to choose between optional settings. Jumpers create shorts between two pins to change the function associated with it. Pin 1 is identified with a square solder pad on the printed circuit board. See the motherboard layout page for jumper locations.
  • Page 71: Led Indicators

    Chapter 4: Motherboard Connections 4.5 LED Indicators Dedicated IPMI LAN port A dedicated IPMI LAN is located on the rear I/O panel and has two LED indicators. The LED on the right indicates connection and activity, while the LED on the left indicates the speed of connection.
  • Page 72 Chapter 4: Motherboard Connections Onboard Power OK LED (LED7) LED7 is an onboard power OK LED. When this LED7 is lit, it means the system is turned on, and all the system power rails are ready. When the system is turned off, or any one of the system power rails fail, this LED will turn off.
  • Page 73: Chapter 5 Software

    If you will be using RAID, you must configure RAID settings before installing the Windows OS and the RAID driver. Refer to the RAID Configuration User Guides posted on our website at www.supermicro.com/support/manuals. Installing the OS 1. Create a method to access the MS Windows installation ISO file. That might be a DVD, perhaps using an external USB/SATA DVD drive, or a USB flash drive, or the IPMI KVM console.
  • Page 74 Chapter 5: Software 3. During Windows Setup, continue to the dialog where you select the drives on which to install Windows. If the disk you want to use is not listed, click on “Load driver” link at the bottom left corner. Figure 5-2.
  • Page 75: Driver Installation

    DVD. (You may also use a utility to extract the ISO file if preferred.) Another option is to go to the Supermicro website at www.supermicro.com/products/. Find the product page for your motherboard, and "Download the Latest Drivers and Utilities".
  • Page 76: Superdoctor ® 5

    5.3 SuperDoctor ® The Supermicro SuperDoctor 5 is a program that functions in a command-line or web-based interface for Windows and Linux operating systems. The program monitors such system health information as CPU temperature, system voltages, system power consumption, fan speed, and provides alerts via email or Simple Network Management Protocol (SNMP).
  • Page 77: Ipmi

    There are several BIOS settings that are related to IPMI. Supermicro ships standard products with a unique password for the BMC ADMIN user. This password can be found on a label on the motherboard.
  • Page 78: Chapter 6 Optional Components

    GPU Support Cable Management Arm TPM security module 6.1 Storage Control Cards Supermicro offers controller cards for some storage options. Storage Protocols Supported The storage drive bays can support SATA or SAS. SATA – The default configuration supports SATA drives.
  • Page 79: Gpu Support

    Chapter 6: Optional Components 6.3 GPU Support Only single-width, half-length GPUs are supported. Installation is the same as PCIe expansion cards. GPU Support Quantity Two double-width, full-length, full-height Power Cable Optional Thermal Kit Upgraded fans: three FAN-0206L4 Conditions Supports up to 400W TDP CPU 6.4 Cable Management Arm The system supports a cable management arm (CMA), which keeps the rear cables organized and clear of the rail mechanisms when the system is extended out the front of the rack for...
  • Page 80 Chapter 6: Optional Components Figure 6-2. Installing the Connectors 3. Slide CMA connector #3 forward onto the two posts on the rear of the left middle rail. It snaps into place. 4. For CMA connector #4, align the metal tabs with the slots on the rear of the left outer rail and push it forward.
  • Page 81: Tpm Security Module

    The JTPM1 header is used to connect a Trusted Platform Module (TPM). A TPM is a security device that supports encryption and authentication in hard drives. It enables the motherboard to deny access if the TPM associated with the hard drive is not installed in the system. Details and installation procedures are at: http://www.supermicro.com/manuals/other/TPM.pdf. • AOM-TPM-9670V...
  • Page 82: Chapter 7 Troubleshooting And Support

    Chapter 7: Troubleshooting and Support Chapter 7 Troubleshooting and Support 7.1 Information Resources Website A great deal of information is available on the Supermicro website, supermicro.com. Figure 7-1. Supermicro Website • Specifications for servers and other hardware are available by the Products option. •...
  • Page 83: Baseboard Management Controller (Bmc)

    Security Center for recent security notices Supermicro Phone and Addresses 7.2 Baseboard Management Controller (BMC) The system supports the Baseboard Management Controller (BMC). BMC is used to provide remote access, monitoring and management. There are several BIOS settings that are related to BMC.
  • Page 84: Before Power On

    Chapter 7: Troubleshooting and Support Before Power On 1. Check that the BMC Heartbeat (LED1) is blinking before the motherboard is turned on. 2. Check that the Onboard Power OK (LED7) on the motherboard is on. 3. Make sure that the power connector is connected to your power supply. 4.
  • Page 85: System Boot Failure

    Chapter 7: Troubleshooting and Support System Boot Failure If the system does not display POST (Power-On-Self-Test) or does not respond after the power is turned on, check the following: 1. Clear the CMOS settings by unplugging the power cord and contacting both pads on the CMOS Clear Jumper (JBT1).
  • Page 86 Chapter 7: Troubleshooting and Support Note: Refer to the product page on our website at http://www.supermicro.com for memory and CPU support and updates. 1. HDD support: Make sure that all hard disk drives (HDDs) work properly. Replace the bad HDDs with good ones.
  • Page 87: Bios Error Beep (Post) Codes

    When BIOS performs the Power On Self Test, it writes checkpoint codes to I/O port 0080h. If the computer cannot complete the boot process, a diagnostic card can be attached to the computer to read I/O port 0080h (Supermicro p/n AOC-LPC80-20). For information on AMI updates, please refer to www.ami.com/products/.
  • Page 88: Crash Dump Using Ipmi

    In the event of a processor internal error (IERR) that crashes your system, you may want to provide information to support staff. You can download a crash dump of status information using IPMI. The IPMI manual is available at https://www.supermicro.com/manuals/other/ BMC_IPMI_X13_H13.pdf. Check IPMI Error Log 1.
  • Page 89: Uefi Bios Recovery

    Warning: Do not upgrade the BIOS unless your system has a BIOS-related issue. Flashing the wrong BIOS can cause irreparable damage to the system. In no event shall Supermicro be liable for direct, indirect, special, incidental, or consequential damages arising from a BIOS update.
  • Page 90 USB device or a writable CD/DVD. Note 1: If you cannot locate the "Super.ROM" file in your drive disk, visit our website at www.supermicro.com to download the BIOS package. Extract the BIOS binary image into a USB flash device and rename it "Super.ROM" for the BIOS recovery use.
  • Page 91 Chapter 7: Troubleshooting and Support Note: At this point, you may decide if you want to start the BIOS recovery. If you decide to proceed with BIOS recovery, follow the procedures below. 4. When the screen as shown above displays, use the arrow keys to select the item "Proceed with flash update"...
  • Page 92 Chapter 7: Troubleshooting and Support 7. Press <Del> continuously during system boot to enter the BIOS Setup utility. From the top of the tool bar, select Boot to enter the submenu. From the submenu list, select Boot Option #1 as shown below. Then, set Boot Option #1 to [UEFI AP:UEFI: Built-in EFI Shell]. Press <F4>...
  • Page 93 Chapter 7: Troubleshooting and Support Note: Do not interrupt this process until the BIOS flashing is complete. 9. The screen above indicates that the BIOS update process is complete. When you see the screen above, unplug the AC power cable from the power supply, clear CMOS, and plug the AC power cable in the power supply again to power on the system.
  • Page 94: Cmos Clear

    Chapter 7: Troubleshooting and Support 7.7 CMOS Clear JBT1 is used to clear CMOS, which will also clear any passwords. Instead of pins, this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS. To Clear CMOS 1.
  • Page 95: Where To Get Replacement Components

    7.9 Where to Get Replacement Components If you need replacement parts for your system, to ensure the highest level of professional service and technical support, purchase exclusively from our Supermicro Authorized Distributors/System Integrators/Resellers. A list can be found at: www.supermicro.com. Click the "Where to Buy"...
  • Page 96: Feedback

    During the warranty period, contact your distributor first for any product problems. 7.11 Feedback Supermicro values your feedback as we strive to improve our customer experience in all facets of our business. To provide feedback on our manuals, please email us at techwriterteam@ supermicro.com.
  • Page 97: Contacting Supermicro

    San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) Sales-USA@supermicro.com (Sales Inquiries) Government_Sales-USA@supermicro.com (Gov. Sales Inquiries) support@supermicro.com (Technical Support) RMA@supermicro.com (RMA Support) Webmaster@supermicro.com (Webmaster) Website: www.supermicro.com Europe Address: Super Micro Computer B.V.
  • Page 98: Appendix A Standardized Warning Statements For Ac Systems

    Supermicro's Technical Support department for assistance. Only certified technicians should attempt to install or configure components. Read this appendix in its entirety before installing or configuring components in the Supermicro chassis. These warnings may also be found on our website at http://www.supermicro.com/about/...
  • Page 99 Appendix A: Warning Statements Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut. Suchen Sie mit der am Ende jeder Warnung angegebenen Anweisungsnummer nach der jeweiligen Übersetzung in den übersetzten Sicherheitshinweisen, die zusammen mit diesem Gerät ausgeliefert wurden.
  • Page 100 Appendix A: Warning Statements . ٌ ‫ا ك ً ف حالة و ٌ يك أى تتسبب ف اصابة جسذ ة ٌ هذا الزهز ع ٌ خطز !تحذ ز‬ ‫قبل أى تعول عىل أي هعذات،يك عىل علن بالوخاطز ال ا ٌجوة عي الذوائز‬ ٍ...
  • Page 101 Appendix A: Warning Statements Warnung Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen. ¡Advertencia! Lea las instrucciones de instalación antes de conectar el sistema a la red de alimentación. Attention Avant de brancher le système sur la source d'alimentation, consulter les directives d'installation. .‫יש...
  • Page 102 Appendix A: Warning Statements Warnung Dieses Produkt ist darauf angewiesen, dass im Gebäude ein Kurzschluss- bzw. Überstromschutz installiert ist. Stellen Sie sicher, dass der Nennwert der Schutzvorrichtung nicht mehr als: 250 V, 20 A beträgt. ¡Advertencia! Este equipo utiliza el sistema de protección contra cortocircuitos (o sobrecorrientes) del edificio.
  • Page 103 Appendix A: Warning Statements Power Disconnection Warning Warning! The system must be disconnected from all sources of power and the power cord removed from the power supply module(s) before accessing the chassis interior to install or remove system components. 電源切断の警告 システムコンポーネントの取り付けまたは取り外しのために、...
  • Page 104 Appendix A: Warning Statements ‫אזהרה מפני ניתוק חשמלי‬ ‫!אזהרה‬ ‫יש לנתק את המערכת מכל מקורות החשמל ויש להסיר את כבל החשמלי מהספק‬ ‫.לפני גישה לחלק הפנימי של המארז לצורך התקנת או הסרת רכיבים‬ ‫يجب فصم اننظاو من جميع مصادر انطاقت وإ ز انت سهك انكهرباء من وحدة امداد‬ ‫انطاقت...
  • Page 105 Appendix A: Warning Statements Equipment Installation Warning! Only trained and qualified personnel should be allowed to install, replace, or service this equipment. 機器の設置 トレーニングを受け認定された人だけがこの装置の設置、 交換、 またはサービスを許可されていま す。 警告 只有经过培训且具有资格的人员才能进行此设备的安装、更换和维修。 警告 只有經過受訓且具資格人員才可安裝、更換與維修此設備。 Warnung Das Installieren, Ersetzen oder Bedienen dieser Ausrüstung sollte nur geschultem, qualifiziertem Personal gestattet werden.
  • Page 106 Appendix A: Warning Statements Restricted Area Warning! This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool, lock and key, or other means of security. (This warning does not apply to workstations). アクセス制限区域...
  • Page 107 Appendix A: Warning Statements ‫אזור עם גישה מוגבלת‬ !‫אזהרה‬ ‫יש להתקין את היחידה באזורים שיש בהם הגבלת גישה. הגישה ניתנת בעזרת‬ (.‫'כלי אבטחה בלבד (מפתח, מנעול וכד‬ . ‫تخصيص هذه انىحذة نترك ب ُ ها ف مناطق محظورة تم‬ ‫، م َ كن انىصىل إن منطقت محظورة فقط من خالل استخذاو أداة خاصت‬ ‫أو...
  • Page 108 Appendix A: Warning Statements Warnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp. Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers. Attention Danger d'explosion si la pile n'est pas remplacée correctement. Ne la remplacer que par une pile de type semblable ou équivalent, recommandée par le fabricant.
  • Page 109 Appendix A: Warning Statements Redundant Power Supplies Warning! This unit might have more than one power supply connection. All connec- tions must be removed to de-energize the unit. 冗長電源装置 このユニッ トは複数の電源装置が接続されている場合があります。 ユニッ トの電源を切るためには、 すべての接続を取り外さなければなりません。 警告 此部件连接的电源可能不止一个,必须将所有电源断开才能停止给该部件供电。 警告 此裝置連接的電源可能不只一個,必須切斷所有電源才能停止對該裝置的供電。 Warnung Dieses Gerät kann mehr als eine Stromzufuhr haben. Um sicherzustellen, dass der Einheit kein trom zugeführt wird, müssen alle Verbindungen entfernt werden.
  • Page 110 Appendix A: Warning Statements ‫אם קיים יותר מספק אחד‬ !‫אזהרה‬ ‫ליחדה יש יותר מחיבור אחד של ספק. יש להסיר את כל החיבורים על מנת לרוקן‬ .‫את היחידה‬ . ‫قد يكون لهذا الجهاز عدة اتصاالت بوحدات امداد الطاقة‬ ‫يجب إ ز الة كافة االتصاالت لعسل الوحدة عن الكهرباء‬ 경고! 이...
  • Page 111 Appendix A: Warning Statements Warnung Wenn das System in Betrieb ist, treten auf der Rückwandplatine gefährliche Spannungen oder Energien auf. Vorsicht bei der Wartung. ¡Advertencia! Cuando el sistema está en funcionamiento, el voltaje del plano trasero es peligroso. Tenga cuidado cuando lo revise. Attention Lorsque le système est en fonctionnement, des tensions électriques circulent sur le fond de panier.
  • Page 112 Appendix A: Warning Statements Comply with Local and National Electrical Codes Warning! Installation of the equipment must comply with local and national electrical codes. 地方および国の電気規格に準拠 機器の取り付けはその地方および国の電気規格に準拠する必要があります。 警告 设备安装必须符合本地与本国电气法规。 警告 設備安裝必須符合本地與本國電氣法規。 Warnung Die Installation der Geräte muss den Sicherheitsstandards entsprechen. ¡Advertencia! La instalacion del equipo debe cumplir con las normas de electricidad locales y nacionales.
  • Page 113 Appendix A: Warning Statements Product Disposal Warning! Ultimate disposal of this product should be handled according to all national laws and regulations. 製品の廃棄 この製品を廃棄処分する場合、 国の関係する全ての法律 ・ 条例に従い処理する必要があります。 警告 本产品的废弃处理应根据所有国家的法律和规章进行。 警告 本產品的廢棄處理應根據所有國家的法律和規章進行。 Warnung Die Entsorgung dieses Produkts sollte gemäß allen Bestimmungen und Gesetzen des Landes erfolgen.
  • Page 114 Appendix A: Warning Statements Hot Swap Fan Warning Warning! Hazardous moving parts. Keep away from moving fan blades. The fans might still be turning when you remove the fan assembly from the chassis. Keep fingers, screwdrivers, and other objects away from the openings in the fan assembly's housing. ファン...
  • Page 115 Electrical Appliance and Material Safety Law prohibits the use of UL or CSA -certified cables (that have UL/CSA shown on the cord) for any other electrical devices than products designated by Supermicro only. 電源コードとACアダプター...
  • Page 116 Verbindungskabeln, Stromkabeln und/oder Adapater, die Ihre örtlichen Sicherheitsstandards einhalten. Der Gebrauch von anderen Kabeln und Adapter können Fehlfunktionen oder Feuer verursachen. Die Richtlinien untersagen das Nutzen von UL oder CAS zertifizierten Kabeln (mit UL/CSA gekennzeichnet), an Geräten oder Produkten die nicht mit Supermicro gekennzeichnet sind. ¡Advertencia! Cuando instale el producto, utilice la conexión provista o designada o procure cables, Cables...
  • Page 117 ‫.قيرح وأ لطع يف ببستي دق ىرخأ تالوحمو تالباك يأ مادختسا .ميلسلا سباقلاو لصوملا مجح‬ ‫ لبق نم ةدمتعملا تالباكلا مادختسا تادعملاو ةيئابرهكلا ةزهجألل ةمالسلا نوناق رظحي‬UL ‫ وأ‬CSA ‫( ةمالع لمحت يتلاو‬UL/CSA) ‫ لبق نم ةددحملاو ةينعملا تاجتنملا ريغ ىرخأ تادعم يأ عم‬Supermicro. 전원 케이블 및 AC 어댑터...
  • Page 118: Appendix B System Specifications

    Appendix B: System Specifications Appendix B System Specifications Processors Single AMD EPYC™ 9004 Series Processor in socket SP5 Chipset System on Chip BIOS AMI BIOS, ACPI 3.0 or later, PCI firmware 4.0 support, BIOS rescue hot-key, SPI dual/quad speed support, RTC (Real Time Clock) wakeup, and SMBIOS 3.0 or later Memory 12 DIMM slots up to 3TB registered ECC DDR5 4800MT/s speed...
  • Page 119 Appendix B: System Specifications Power Supply PWS-1K23A-1R, 1000W/1200W redundant modules, 80Plus Platinum level* AC Input 1000W: 100-127Vac / 15A-12A / 50-60Hz 1200W: 200-240Vac / 8.5A-7A / 50-60Hz +12V Max: 83A / Min: 0A (100Vac-127Vac) Max: 100A / Min: 0A (200Vac-240Vac) 5V SB Max: 4A / Min: 0A *Full redundancy based on configuration and application load.
  • Page 120 Appendix B: System Specifications...

Table of Contents