Page 1
Modified on: Thu, 16 Sep, 2021 at 3:31 PM Aeotec Water Sensor 7 Basic. Aeotec Water Sensor 7 has been crafted as a safety sensor to help detect and prevent floods and water leaks using Z- Wave Plus. It is powered by Aeotec’s...
Page 2
Important safety information. Please read this and other device guides carefully. Failure to follow the recommendations set forth by Aeotec Limited may be dangerous or cause a violation of the law. The manufacturer, importer, distributor, and/or reseller will not be held responsible for any loss or damage resulting from not following any instructions in this guide or in other materials.
2022. 02. 28. 15:41 Water Sensor 7 Pro/Basic user guide : Aeotec Help Desk Quick Start Installation of Water Sensor 7 Basic. Open the cover by pressing the clip on the side and pulling the cover upwards. Insert a fresh 1 * 1/2 AA battery, but pay attention to the polarity Install your Water Sensor 7 Basic.
Page 4
2022. 02. 28. 15:41 Water Sensor 7 Pro/Basic user guide : Aeotec Help Desk Classic Inclusion 1. Set your Z-Wave controller into pairing mode. 2. Triple-click the tamper switch on Water Sensor 7 - this begins to blink five times 3.
2022. 02. 28. 15:41 Water Sensor 7 Pro/Basic user guide : Aeotec Help Desk When operation button is Short Pressed the LED blinks red three LowBatt time (1 sec duty cycle) If either Tamper Switch 1 or 2 is activated the device blinks red one time with ½...
Page 6
2022. 02. 28. 15:41 Water Sensor 7 Pro/Basic user guide : Aeotec Help Desk In order to send your sensors new configuration commands from your Z-Wave controller or gateway, it will need to be woken up. 1. Wake Up the device by removing the cover.
2022. 02. 28. 15:41 Water Sensor 7 Pro/Basic user guide : Aeotec Help Desk Parameter setting. 3. Visual LED indications Parameter: 3 Size: 1 Byte Default Value: 7 Description: This parameter defines when the red LED will indicate events. Disabling all indications may extend battery life.
Page 8
2022. 02. 28. 15:41 Water Sensor 7 Pro/Basic user guide : Aeotec Help Desk This is the BASIC command value sent in case of On even 0 - 99 - Value 255 - On 8. BASIC command value sent to 2nd Association Group on Off event...
Page 9
2022. 02. 28. 15:41 Water Sensor 7 Pro/Basic user guide : Aeotec Help Desk 1- Reset all Parameter settings to their default settings. 1431655765 - (0x55555555) Completely factory reset sensor and send device reset locally notification Preview https://help.aeotec.com/support/solutions/articles/6000228221-water-sensor-7-basic-user-guide-zwa018-...
Need help?
Do you have a question about the ZWA018 and is the answer not in the manual?
Questions and answers