Connection of the bottom plate heater

1
Using the appropriate cable, connect the power supply cable to
the appropriate terminals as shown on the wiring diagram below.
X2M
15a 15
1
2
X1Y
bottom plate heater
2
Fix the cable(s) with cable ties to the cable tie mountings to
ensure strain relief.
3
When routing out cables, make sure that these do not obstruct
mounting of the indoor unit cover.
4
Select the appropriate field setting values for the bottom plate
heater. See "[F-02]", "[F-03]", and
INFORMATION
Bottom plate heater is only applicable in combination with
ERLQ_AA/AB/BA or in case of optional EKBPHT kit. The
ERLQ_CA outdoor unit controls the bottom plate heater
internally by the outdoor unit pcb.

Connection of the pump

Pump requirements
Power supply: 230 V AC
Maximum running current: 3.5 A
Procedure
1
Use the appropriate cable, connect the cable to the appropriate
terminals as shown on the wiring diagram below.
X7M
1
2
M
2
Fix the cable(s) with cable ties to the cable tie mountings to
ensure strain relief.
Connection to a benefit kWh rate power supply
Electricity companies throughout the world work hard to provide
reliable electric service at competitive prices and are often authorized
to bill clients at benefit rates. E.g. time-of-use rates, seasonal rates,
Wärmepumpentarif in Germany and Austria, ...
This equipment allows for connection to such benefit rate power
supply delivery systems.
Consult with the electricity company acting as provider at the site
where this equipment is to be installed to know whether it is
appropriate to connect the equipment in one of the benefit kWh rate
power supply delivery systems available, if any.
When the equipment is connected to such benefit kWh rate power
supply, the electricity company is allowed to:
interrupt power supply to the equipment for certain periods of
time;
demand that the equipment only consumes a limited amount of
electricity during certain periods of time.
The indoor unit is designed to receive an input signal by which the
unit switches into forced off mode. At that moment, the outdoor unit
compressor will not operate.
Installation manual
21
"[F-04]" on page
38.
Possible types of benefit kWh rate power supply
Possible connections and requirements to connect the equipment to
such power supply are illustrated in the figure below:
[d-01]=1
1
L N
1
2
S2S
3
L N
2
1
S2S
2
3
3
L N
1
2
S2S
3
3
17 18
1 Benefit kWh rate power supply box
2 Receiver controlling the signal of the electricity company
3 Power supply to outdoor unit (refer to the installation
manual delivered with the outdoor unit)
4 Voltage free contact to indoor unit
5 Normal kWh rate power supply
When the outdoor unit is connected to a benefit kWh rate power
supply, the voltage free contact of the receiver controlling the benefit
kWh rate signal of the electricity company must be connected to
clamps 17 and 18 of X2M (as illustrated in the figure above).
When parameter [d-01]=1 at the moment that the benefit kWh rate
signal is sent by the electricity company, that contact will open and
the unit will go in forced off mode
When parameter [d-01]=2 at the moment that the benefit kWh rate
signal is sent by the electricity company, that contact will close and
the unit will go in forced off mode
Type 1
This type of benefit kWh rate power supply is not interrupted.
Type 2
This type of benefit kWh rate power supply is interrupted after elapse
of time.
Type 3
This type of benefit kWh rate power supply is interrupted immediately.
(1) When the signal is released again, the voltage free contact will close and
the unit will restart operation. It is therefore important to leave the auto
restart function enabled. Refer to
(2) When the signal is released again, the voltage free contact will open and
the unit will restart operation. It is therefore important to leave the auto
restart function enabled. Refer to
[d-01]=2
1
L N
1
2
S2S
4
3
L N
2
1
S2S
2
4
3
3
L N
1
2
S2S
4
3
L N
5
4
30 31
X2M
A1P
X40A
(1)
.
(2)
.
"[3] Auto restart" on page
28.
"[3] Auto restart" on page
28.
EKHBX016BB3V3S
Indoor unit for air to water heat pump system
4PW62598-1 – 10.2010
4
4
4