EN
15 Technical data
NOTE In the table below all values are minimum performance values and "must have" unless indicated otherwise.
Nominal voltage
Nominal capacity
Cycle life
Charge
Charging temperature range
Charging voltage
Recommended float charging voltage
Recommended charging current
Allowed max charging current
Discharge
Discharging temperature range
Output voltage range
Max continuous discharge current
Surge discharge current
Pulse discharge current
Pulse discharge current
Low voltage end-of-discharge voltage
Mechanical Characteristics
Dimensions
Weight
Ingress protection
Storage
Storage temperature and humidity
range
10
100 A max starting temp of 77 °F (25 °C)
120 A for 30 min starting temp of 77 °F (25 °C)
200 A for 5 s starting temp of 77 °F (25 °C)
400 A for 3 s starting temp of 77 °F (25 °C)
Length: 313.9 mm
1 Week
1 Month
6 Months
100 Ah
100 Ah
3000-5000 cycles
-20 °C ... 55 °C
14.4 V Recommended (14.6 V max.)
50 A
100 A
-20 °C ... 55 °C
10 V ... 14.6 V
9.2 V ± 0.1 V
Width: 174.1 mm
Height: 221 mm
11 kg
-20 °C ... 50 °C, 45 % ... 85 % RH
-20 °C ... 45 °C, 45 % ... 85 % RH
-20 °C ... 40 °C, 45 % ... 85 % RH
300 Ah
12.8 V
300 Ah
14.1 V
120 A
200 A
200 A starting temp of 77 °F (25 °C)
400 A for 10 min starting temp of 77 °F (25 °C)
1000 A for 1 s starting temp of 77 °F (25 °C)
-
Length: 498 mm
Width: 379 mm
Height: 206 mm
33.1 kg
IP67