Installation

Set up the device horizontally
Observe the following conditions:
 D
• Ensure that the connection to the power supply is at least 2 m from the edge of the pond.
• Place the device so that the filter housing is always below the water level.
• Place the device horizontally on a firm, mud-free surface.
Hang up the device
Observe the following conditions:
 E
• Ensure that the connection to the power supply is at least 2 m from the edge of the pond.
• Place the device so that the filter housing is always below the water level.
• Screw the two screws into the filter base and hang the device on the two screws with a cord.
Fasten the cord on the side of the pond.
Connection
Allocation for pump connection cable:
A = 1.0 mm2
A = AWG 18
Commissioning/start-up
NOTE
The unit will be destroyed if it is operated with a dimmer. It contains sensitive electrical compo-
nents.
Do not connect the unit to a dimmable power supply.
Switching on: Connect the unit to the mains. The unit switches on immediately.
Switching off: Disconnect the unit from the mains.
 F
The viewing window shows that the UVC lamp in the device is working.
U
white
L1
220 – 240 V AC
black
L2
green
EN