TRAINER POINT: Service & Maintenance Manual - rev. 1.2
2. TECHNICAL CHARACTERISTICS
2.1. MECHANICAL CHARACTERISTICS
Width
Length
Height
Weight
2.2. ELECTRICAL CHARACTERISTICS
Mains voltage
Frequency
Consumption
Fuses
The mains voltage is set by means of a special soldered jumper on the power supply
circuit board. An incorrect voltage setting can cause irreversible damage to the power
supply unit.
2.3. AMBIENT SPECIFICATIONS
Temperature
Humidity
2.4. CONFORMITY TO REGULATIONS
The equipment conforms to the following directives:
EMI
Safety
Directive
31 cm
25 cm
16 cm
2.5 kg
115 - 230 VAC
50 - 60 Hz
~ 5 Watt - 30 mA
5x20 300 mA fast-blow
Operating
from 5° to 35° C
Storage
from -20 to 55° C
Operating
from 30% to 80% non-condensing
Storage
from 5% to 85% non-condensing
Europe
EN 50081-1:92
EN 50082-1:92
EN 60950:92+A4:97
73/23/EEC
93/68/EEC
89/336/EEC
USA
UL 1950
Page 2.1