Connecting Compressed Air; Connecting The Cutting Burner; Connecting The Earthing Cable; Using The Device - Parkside PPS 40 C3 Operation And Safety Notes Translation Of The Original Instructions

Table of Contents

Advertisement

Available languages

Available languages

The device must not be used as a storage
place and tools or other items must not
be placed on the device.
It must be operated in a dry and
well-ventilated working environment.

• Connecting compressed air

PLEASE NOTE!
fThis device is designed for operating
pressure (output pressure at the com-
pressor) of up to 6.3 bar. Please bear in
mind that the pressure can lower while
setting the air pressure. Thus, in a hose
length measuring 10 m and an internal
diameter of 9 mm it drops by approx.
0.6 bar.
The compressed air source must have a filter
and regulator.
Connect the compressed air hose
the back of the plasma cutter
compressed air connection
insert the side of the compressed air hose
16
without quick connector into the
compressed air connection
plasma cutter
1
The pressure can be set via the rotary
21
knob
on the condensate separator
(see Fig. I–L). Select a pressure of
4–4.5 bar.
In order to release the compressed air
16
hose
, you must press the locking
mechanism of the compressed air
connection
20
and pull out the com-
pressed air hose
(see Fig. I).
• Connecting the cutting
burner
Pull the cover cap
burner connection socket
16
GB
16
1
to the
20
. To do so,
20
of the
(see Fig. I).
16
at the same time
12a
off the plasma
12
.
Insert the plasma burner plug
plasma burner connection socket
and tighten the union nut hand-tight
(see Fig. A+B).
Insert the plasma burner control plug
into the plasma burner control socket
and tighten the union nut hand-tight
(see Fig. A+B).
• Connecting the earthing
cable
Connect the earthing clamp device plug
with the earthing clamp connection socket
. Then connect the earthing clamp plug
11
with the earthing clamp connecting plug
Make sure that the connecting shaft is first
connected and then turned. The connecting
shaft of the earthing clamp device plug
must point upwards when plugging in.
After plugging in, the connecting shaft
on
must be rotated in a clockwise direction
until it reaches the stop, in order to lock
it in place (see Fig. A+B). This does not
require force!

• Using the device

• Operation

1. Set the plasma cutter
well ventilated area.
2. Position the machine in the vicinity of the
workpiece.
3. Press the on/off switch
4. Clamp the earthing terminal
workpiece to be cut and make sure that
there is a good electrical contact.
5. Set the cutting current on the current
controller
rupted the cutting current must be set
higher if necessary. If the electrode burns
through frequently, then the cutting
current must be set lower.
up in a dry and
1
17
.
13
. If the arc beam is inter-
7
into the
12
6
10
5a
5
.
5b
5a
4
onto the

Advertisement

Table of Contents
loading

This manual is also suitable for:

435169 2304

Table of Contents