Putting Into Operation - Fieldmann FVC 2011-EK Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

3. PUTTING INTO OPERATION

Installation
Submersible pumps are installed as follows:
in a permanent position with a rigid pipe.
in a permanent position with a fl exible pipe.
You should never install the pump by hanging it on the outlet hose or power cord without additional support.
The submersible pump must be hung on a holder, or it must be placed on the bottom of the tank.
For the pump to function correctly the bottom part of the tank must be protected against any kind of dirt (applies to
clean water pumps) and against any larger residue (for the size of dirty material see the technical specifi cations
of the individual models).
If the water level declines too much, any residue in the pumping pit will quickly dry out and prevent the pump
from starting again. It is therefore essential to regularly inspect the submersible pump (by starting it).
The fl oat is set up in such a way that the pump may be started immediately.
After carefully reading these instructions you can prepare your pump for operation, however, keep the following
points in mind:
Check that the pump is standing on the bottom of the tank.
Check that the outlet hose has been attached correctly.
Check that the electrical connection is 230 V ~ 50 Hz.
Check that the power socket is in good condition.
Ensure that the moisture from the water can never get to the electrical power source.
Prevent the pump from running empty.
Before putting the pump into operation, please check the following points:
The switching fl oat is installed in such a way that it is possible to reach the activation level or the shut off level
with only a small amount of force. After checking this installation, place the pump into a tank with water and
carefully lift the switching fl oat by hand and then put it down again. During this activity watch that the pump
has started and then turned itself off.
Ensure that the distance between the switching fl oat and the pawl holder is not too small. It is not possible to
guarantee correct operation when the gap is too small.
As soon as you set the switching fl oat, check that it is not touching the underlay before the pump turns off.
The activity position of the switching fl oat can be set by adjusting the fl oat in the holder of the pawl.
ATTENTION: Danger of running when empty.
Note: The tank for the pump should have the minimum dimensions of 40 × 40 × 50 cm (height × width
× depth), for the fl oat to freely move with the switch.
Connecting to the mains
Your new submersible pump is equipped with a power plug, preventing discharge, meeting strict norms. The pump
is designed to be connected to a safety power socket 230 V ~ 50 Hz. Check that it is in perfect condition. Insert the
plug into the socket and the pump is ready for use.
SUBMERSIBLE PUMP
Putting into operation
USER'S MANUAL
4
EN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fvc 2013-ek

Table of Contents