Convergence Adjustment; Presetting Modes Adjustment - Hitachi CM715ET Service Manual

Hide thumbs Also See for CM715ET:
Table of Contents

Advertisement

H. Convergence Adjustment
Input R+B and R+G signals, make sure convergence within specified (if not 4 pole and 6 pole). A zone =
0.3MM., B zone 0.4MM. (X) < 0.4MM, (Y) < 0.4MM.
NOTE : 1 A area = 230mm (circle)
2 B area = 306 x 230 mm
I. Presetting Modes Adjustment
There are totally 12 preset modes, individual adjust is needed.
1. H-SIZE adjust : adjust control key to get H-SIZE = 306 ± 2mm.
2. H-CENTER adjust : adjust control key to get center within ± 2mm
3. V-SIZE adjust : adjust control key to get V-SIZE = 230 ± 2mm
4. V-CENTER adjust : adjust control key to get center within ±2mm
5. Geometric adjust : adjust control key to get minimize distortion.
6. H-linearity check : check and make sure linearity meet spec.
7. V-linearity check : check and make sure linearity meet spec.
8. Geometric check : check and make sure geometric meet spec.
9. Get into OSD select EE-USER item, press ENTER till OSD disappear then turn off power, disconnect JP1, turn
on power again, make sure all of the alignment parameters has been stored properly, make H-SIZE adjust range
can OVER SCAN and -5%, PHASE adjust range >15mm, V-SIZE adjust range can OVER SCAN and -6%,
V-CENTER adjust range >20mm and make sure TILT adjust work properly.
(CROSS HATCH PATTERN 10X8)
2(MAX - MIN)
X100%
MAX + MIN
Any : <10%
Adjacent : <5%
2(MAX - MIN)
X100%
MAX + MIN
Any : <10%
Adjacent : <6%
10

Advertisement

Table of Contents
loading

Table of Contents