Siemens SK26E222EU Information For Use page 37

Table of Contents

Advertisement

Fault
E:18 or indicator for
water supply lights up.
1
E:22 lights up.
E:24 lights up.
1
Depending on the appliance specifications
Cause and troubleshooting
Turn on the water tap.
The flow rate must be at least 10 l/min when the
water supply is open.
The filters in the water connection of the supply or
AquaStop hose are blocked.
Switch off the appliance.
1.
Pull out the mains plug.
2.
Turn off the water tap.
3.
Unscrew the water connection.
4.
Remove the filter from the supply hose
5.
Clean the filter.
6.
Re-insert the filter in the supply hose.
7.
Screw the water connection back on.
8.
Check the water connection for leaks.
9.
Restore the power supply.
10.
Switch the appliance on.
11.
Filters are soiled or blocked.
Clean the filters.
→ "Cleaning filters", Page 34
Wastewater hose is blocked or kinked.
Reposition the wastewater hose without kinks.
1.
Remove residues.
2.
Siphon connection is still sealed.
Check the connection to the siphon and open if ne-
cessary.
Cover of the wastewater pump is loose.
Secure the cover of the Wastewater pump
→ Page 48 so it clicks into position.
Troubleshooting en
37

Advertisement

Table of Contents
loading