Samsung Max Heat DVM S2 Technical Data Book page 24

Table of Contents

Advertisement

2. Specification
DVM S2 (460V)
Model Name
Outdoor unit module 1
Outdoor unit module 2
Outdoor unit module 3
Outdoor unit module 4
TransmissionCable
Wiring
Connections
Power supply intake
Type
Refrigerant
Factory Charging
Sound Pressure
Sound
Sound Power
Net Weight
Shipping Weight
Net Dimensions
External
Dimension
(WxHxD)
Shipping Dimensions (WxHxD)
Operating
Cooling
Heating
Temp. Range
NOTE
• Specification may be subject to change without prior notice.
• Specification comply with EN14511.
1) Nominal capacities are based on (Equivalent refrigerant piping : 25ft, Level differences : 0ft);
- Cooling : Indoor temperature 80℉ DB, 67℉ WB / Outdoor temperature 95℉ DB, 75℉ WB
- Heating : Indoor temperature 70℉ DB, 60℉ WB / Outdoor temperature 47℉ DB, 43℉ WB
2) The standard allowed combination ratio of the total rated indoor unit capacity over the rated outdoor unit capacity is 50~130%. Combination ratio of up to
184% is allowed depending on operation mode, minimum operation ratio and connected indoor unit models.  DVM Pro 2 design software supports
designing over 130% based on system design.  Refer to the "Design Procedure & Combination Ratio" section of this document for details
3) IIf outdoor unit is located in a higher position than indoor unit, level difference is 361ft or under.
(If the level difference is higher than 164ft, the PDM kit should be installed)
*PDM kit: Pressure Drop Modulation kit
4) These products contain R410A which is fluorinated greenhouse gas.
5) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
6) Sound power level is an absolute value that a sound source generates.
Sound pressure level is a relative value, depending on the distance and acoustic environment.
Sound values are obtained in an anechoic room.
Sound values of multi comvination are theoretical values based on sound results of individual installed units.
7) Cooling operation is possible at -15℃(5℉) or higher if satisfied following conditions.
(If the outdoor temperature below -5℃(23℉), wind(snow) protection duct must be installed on the suction side of the heat exchanger and at least 50%capacity of the
connected indoor units must be operated.) However, if the outdoor unit is installed below the indoor unit, cooling operation is possible only at -5℃(23℉) or higher.
8) External static pressure of the model installed as a combined module follows the external static pressure of each single unit.
• For more information regarding capacity correction, please refer to capacity tables available at www.SamsungHVAC.com/downloads.
AM072BXVTJH/AA
Min.
Remark
-
-
Both indoor and outdoor unit Both indoor and outdoor unit Both indoor and outdoor unit
-
lbs (kg)
Cooling
dB(A)
Heating
dB(A)
dB(A)
lbs (kg)
lbs (kg)
1,295 x 1,695 x 765
inch
51 x 66-3/4 x 30-1/8
1,363 x 1,887 x 829
inch
53-11/16 x 74-5/16 x 32-11/16 53-11/16 x 74-5/16 x 32-11/16 53-11/16 x 74-5/16 x 32-11/16
℉ (℃)
5 ~ 122 (-15 ~ 50)
℉ (℃)
-22 ~ 75 (-30 ~ 24)
AM096BXVTJH/AA
-
-
-
-
0.75
0.75
F1, F2
F1, F2
R410A
R410A
17.6 (8.0)
23.1 (10.5)
55.0
57.0
56.0
58.0
74.0
77.0
571 (259)
661 (300)
608 (276)
699 (317)
1,295 x 1,695 x 765
51 x 66-3/4 x 30-1/8
1,363 x 1,887 x 829
5 ~ 122 (-15 ~ 50)
-22 ~ 75 (-30 ~ 24)
AM120BXVTJH/AA
-
-
-
-
-
-
-
-
0.75
F1, F2
R410A
23.1 (10.5)
59.0
59.0
79.0
661 (300)
699 (317)
1,295 x 1,695 x 765
51 x 66-3/4 x 30-1/8
1,363 x 1,887 x 829
5 ~ 122 (-15 ~ 50)
-22 ~ 75 (-30 ~ 24)