Inverter Unexpectedly Or Frequently Shutting Down; Multiple Inverter Installations; Internet Connection Problems - Redback SI5000 Owner's Manual

Smart inverter
Table of Contents

Advertisement

Troubleshooting

Inverter unexpectedly or frequently shutting down

The inverter may shut down or isolate itself from the grid if it detects supply conditions that may cause damage to the inverter;
or create an unsafe situation. Incident causes can be diagnosed by examining the data available on the portal. Unexpected
shutdowns may occur in the following circumstances:
CAUSE
A grid outage (blackout) is occurring
Grid supply is not of acceptable
quality, as defined by AS/NZS 4777.2.
If internal temperature is greater than
60
C.
°
*You may not have access to all chart parameters. Contact your installer or Redback if you require access.

Multiple inverter installations

Your installation may include 1-3 SI-series inverters, usually connected to different phases, and these inverters operate
independently except in one situation: if any inverter encounters a fault and needs to shut down, then the other two inverters
will also shut down immediately. When the first inverter recovers, or is isolated from PV and the Grid, the other two inverters
will restart.

Internet connection problems

Occasionally, your inverter may lose internet connection and be reported as "offline". Ethernet connected systems usually self-
repair after a system restarts. Wi-Fi problems usually require that the system is re-onboarded. The most common causes of
"offline" reports are:
INDICATION
Change of Internet Service Provider e.g., Telstra,
Optus, TPG, Dodo etc
New router or modem
Change of Network name or SSID
Changed settings in router or modem
Changed Wi-Fi or Network password
Too many users or devices on your home Wi-Fi
network
Wi-Fi signal is weak or variable due to obstructions
or distance between the inverter and your Wi-Fi
router's antenna.
16 Owner's Guide – Redback Smart Inverter – v1.4
RELEVANT CHARTS FOR
DIAGNOSIS (IN PORTAL) *
Grid-Status
Grid-Voltage
Grid-Frequency
Grid-Status
Inverter- Temperature
Battery Cabinet-Temp.
CONNECTION AFFECTED REMEDY
ETHERNET
COMMENT
Wait for the grid to be restored. Your system will restart
automatically.
Ask your installer or electricity provider to investigate if
grid supply is often poor.
Output is reduced above 45
WI-FI
Ethernet: Restart the system.
Wi-Fi: Restart the system and re-onboard.
Wi-Fi: Restart and re-onboard
Limit users or devices; upgrade Wi-Fi router;
connect inverter using ethernet.
Experiment with Wi-Fi router locations; use a
Wi-Fi extender; connect using ethernet.
C.
°