Notices for Installation
Installation Site of Indoor Unit
1. The air inlet and outlet should be away from the obstructions. Ensure the air can be blown
through the whole room.
2. Select a site where the condensing water can be easily drained out, and where it is easily con-
nected for outdoor unit.
3. Select a place where it is out of reach of children.
4. Select the place where the wall is strong enough to withstand the full weight and vibration of
the unit.
5. Be sure to leave enough space to allow access for routine maintenance. The installation site
should be 250cm or more above the fl oor.
6. Select a place about 1m or more away from TV set or any other electric appliance.
7. Select a place where the fi lter can be easily taken out.
8. Make sure that the indoor unit is installed in accordance with installation dimension instructions.
9. Do not use the unit in the laundry or by swimming pool etc.
Installation Site of Outdoor Unit
1. Select a site where noise and outfl ow air emitted by unit will not annoy neighbors.
2. Select a site where there is suffi cient ventilation.
3. Select a site where there is no obstruction blocking the inlet and outlet.
4. The site should be able to withstand the full weight and vibration.
5. Select a dry place, but do not expose the unit to direct sunlight or strong wind.
6. Make sure that the outdoor unit is installed in accordance with the installation instructions, and is
convenient for maintenance and repair.
7. The height diff erence between indoor and outdoor units is within 5 m, and the length of the connect-
ing tubing does not exceed 10 m.
8. Select a place where it is out of reach of children.
9. Select a place which will not block pedestrian passage and infl uence the city appearance.
Safety Precautions for Electric Appliances
1. A dedicated power supply circuit should be used in accordance with local electrical safety regula-
tions.
2. Don't drag the power cord emphatically.
3. The unit should be reliably earthed and connected to the special earth device by the professionals.
4. The air switch must have the functions of magnetic tripping and heat tripping to prevent short
circuit and overload.
5. The minimum distance between the unit and combustive surface is 1.5m.
6. The appliance shall be installed in accordance with national wiring regulations.
7. An all-pole disconnection switch with a contact separation of at least 3mm in all poles should be
connected in fi xed wiring. For models with a power plug, make sure the plug is within reach after
installation.
8. Including an air switch with suitable capacity, please note the following table. Air switch should
be included magnet buckle and heating buckle function, it can protect the circuitshort and over-
load. (Caution: please do not use the fuse only for protect the circuit)