30" DUAL FUEL SLIDE-IN RANGE INSTALLATION INSTRUCTIONS
(Models with Sealed Top Burners)
NOTES:
@
Do not pinch the power supply cord between the range and the wall.
&
Do not seal the range to the side cabinets.
24" (61 cm) minimum clearance between the cooktop and the bottom of the cabinet when the
bottom of wood or metal cabinet is protected by not less than 1/4" (0.64 cm) flame retardant
&
millboard covered with not less than No. 28 MSG sheet metal, 0.015" (0.4 mm) stainless steel,
0.024" (0.6 mm) aluminum, or 0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance when the cabinet is unprotected.
@
For cutouts below 22 7/8"(58.1 cm), appliance will slightly show out of the cabinet.
©
Allow at least 20" (50.8 cm) clearance for door depth when it is open.
22 7/8" (58.1 cm) min.
2
23 1/4" (59.05 cm) max.
[
(see Note 4)
—»
4
«—
11/8"
(2.86 cm}
FRONT
of
——
F —>
CABINET
Ref.
Door Open
(see note 5)
Side Panel
A, HEIGHT
C, COOKTOP!
D. TOTAL DEPFIH 10 | BE. CUTOUT WIDIH® =
F CUIOUT DEPIn
G. HEIGHT
(Under Cookiop)
an
WIDIE
FRONT OF RANGE | (Counterion and cabinel)
OP COUNTERTOP
35 7/8" (911m)
30"
31"
28 5/16" (71.9em)
3041/16"
21 3/4" (55.2cm) Min.
36 5/8" (93cm)
(76.2cm)|
(80cm)
(76.2£0.15¢m)
22 1/8" (56.2cm) Max
Max.
36 5/8" (93cm)
24" (61cm) Min. with | 35 7/8" (91.1em)
backguard