Typical application examples

• The application examples given below are for illustration purposes only .
• When the SAMSUNG Air-to-Water Heat Pump system is used in series with another heat source (e . g . gas boiler),
WARNING
ensure that the return water temperature not exceed 55 °C .
• The unit is only to be used in a closed water system . Application in an open water circuit can lead to excessive
corrosion of the water piping .
• SAMSUNG can not be responsible for incorrect or unsafe situations in the water system . Make sure that the
boiler, radiators, convectors, solar collectors, UFHs, FCUs, additional pumps, pipings, and controls in the water
system are in accordance with relevant local laws and regulations under the installer's responsibility .
• SAMSUNG shall not be held liable for any damage resulting from not observing this rule .
• SAMSUNG do not provide specific water system components such as Pressure relief valve, Air vent valve, buffer
tank and etc . Installers and end-users shall consider how to install the above designated components in overall
water system depending on the installation conditions . If the components are not installed in appropriate
location, the water system can not be operated as designed .
❋ ❋ The below examples are for illustration purposes only .
Application 1: Space heating
Outdoor
Our Supply Range
Outdoor unit
Indoor
Hydro Unit
Water
pump #2
Tw2_z2
Water
pump #1
Balancing Vessel
ENGLISH-8
Room Controller
Zone Control
45°C
Supply Header
Return Header
Radiators or Convectors
35°C
Supply Header
Tw2_z1
Return Header
Under-Floor Heating Coils