Samsung AE160ANYD H Series Installation Manual page 27

Air to water heat pump
Table of Contents

Advertisement

Wiring work
No.
Part code
CNS051
CNS062/
CNS063
CNS046
CNS301
CNP101
Part name
#1: SG READY1 SIGNAL
#2: OPTION TEMP . ( 10kΩ @ 25 °C)
#3: GND
#4: GND
#5: SG READY2 SIGNAL
#6: ZONE2 TEMP . (10kΩ @ 25 °C)
#7: GND
#8: GND
#9: DRY CONTACT1 SIGNAL
#10: ZONE1 FLOW TEMP . (10kΩ @ 25 °C)
#11: GND
#12: GND
DIGITAL INPUT/
OUTPUT
#13: DRY CONTACT2 SIGNAL
#14: ZONE2 FLOW TEMP . (10kΩ @ 25 °C)
#15: GND
#16: GND
#17: DRY CONTACT3 SIGNAL
#18: NO CONNECT
#19: GND
#20: NO CONNECT
#21: DRY CONTACT4 SIGNAL
#22: NO CONNECT
#23: GND
#24: NO CONNECT
#1~#4: EEV CONTROL PWM SIGNAL
EEV
#5: DC 12V
#6: DC 12V (CNS063 ONLY)
#1: PV(Photovoltaic) Control Signal / Peak
PV/Peak power
power control Signal
control SIGNAL
#2: GND
DOWNLOAD
EARTH
#1: EARTH
ENGLISH-26
Terminal
Terminal description
DC INPUT
DIGITAL INPUT
DIGITAL GROUND
DIGITAL GROUND
DC INPUT
DIGITAL INPUT
DIGITAL GROUND
DIGITAL GROUND
DC INPUT
DIGITAL INPUT
DIGITAL GROUND
DIGITAL GROUND
DC INPUT
DIGITAL INPUT
DIGITAL GROUND
DIGITAL GROUND
DC INPUT
-
DIGITAL GROUND
-
DC INPUT
-
DIGITAL GROUND
-
DC OUTPUT
DC OUTPUT
DC OUTPUT
DC INPUT
DIGITAL GROUND
EARTH

Advertisement

Table of Contents
loading

Table of Contents