Samsung AE160ANYD H Series Installation Manual page 36

Air to water heat pump
Table of Contents

Advertisement

Tightening Torque (kgf • cm)
M3
M5
Connection of the backup heater power supply
• Do not use a power supply shared by other appliances . Each components for outdoor unit, indoor unit, backup
heater and booster heater has the dedicated power supply .
CAUTION
Model
AE160ANYDEH
AE160ANYDGH
❋ ❋ Circuit Breaker(ELCB, ELB, MCCB etc . ) s written above are already included in the hydro unit .
ELCB : Earth leakage circuit breaker
ELB : Earth leakage breaker
MCCB : Molded case circuit breaker
1 phase
1 Phase
ELCB
Separate the solderless terminal up and down to prevent it being get
loosen . Place the thin cable upward and the thick cable downward . Secure
the power cable with the cable tie .
5~7 . 5
20 ~ 30
Heater capacity (kW)
6
6
3 phase
1 Phase
ELCB
ENGLISH-35
Solderless terminal
ELCB capacity (A)
40
20
Booster heater (DHW)
1L
3 Phase
ELCB
Cable tie
Thin cable
Thick cable
2N
L
N
DHW Tank