Scanport Link Connection; Cable Requirements; 1305 Drive - Allen-Bradley 1203-GD2 User Manual

Rs232/422/485 (using df1 protocol)
Hide thumbs Also See for 1203-GD2:
Table of Contents

Advertisement

Chapter 3
Installation

SCANport Link Connection

3-16

Cable Requirements

SCANport cables are available in either Male to Male or Male to Female
configuration. Cables of up to 10 meters (33 feet) can be connected from
the master to the SCANport device (A in Figure 3.9). If a Port Expander is
used as shown in Figure 3.9, the cable length from the master to the Port
Expander must be subtracted from the cable length used to connect the
device to the expander (B1 + C = max 10 meters).

1305 Drive

An Allen-Bradley SCANport link cable is used to make the connection
between the Communications Module and the drive (Figure 3.9).
Figure 3.9
SCANport Connection on Communications Module
1305 Drive
Port 2
Port 1
A
Optional
Male–Female
Cable
Human Interface
Module
IMPORTANT: The maximum cable distance between any two devices
cannot exceed 10 meters (33 feet) of cable.
For example: A + B1 + C
A + B2 + C
B1 + B2
Port Expander
2
3
4
5
C
Optional
B1
Male–Male
Cable
Communication
Module
10 meters
10 meters
10 meters
B2
Communication
Module
AB0407B

Advertisement

Table of Contents
loading

This manual is also suitable for:

1203-gk21203-gm2

Table of Contents