2–16
Installation
Connecting the SCANport
Link
Human Interface Module
Publication 1203–5.1 –– July, 1997
SCANport cables are available in either Male–to– Male or
Male–to–Female configuration. You can connect cables of up to 10
meters (33 feet) from the master to the SCANport device (A in
Figure 2.14). If you use a port expander as shown in Figure 2.14,
subtract the cable length from the master to the port expander from
the cable length used to connect the device to the expander (B1+ C =
maximum 10 meters).

1305 Drive

An Allen-Bradley SCANport link cable is used to make the
connection between the communications module and the drive
(Figure 2.14).
Figure 2.14
SCANport connection on Remote I/O
1305 Drive
Port 1
A
Optional
Male–Female
Cable
Important: The maximum cable distance between any two master
1336 PLUS (7.5 – 500HP) and 1336 FORCE
Refer to the product manual for connection information. On larger
horsepower 1336 PLUS and 1336 FORCE drives with an open
remote I/O module mounted in the drive, you do not need a separate
SCANport cable connection.
Port Expander
Port 2
2
3 4
C
Optional
Male–Male Cable
B1
Remote I/O
Communication Module
devices cannot exceed 10 meters (33 feet) of cable. For
example, B1 + C = maximum of 10 meters or B1 + B2
= maximum of 10 meters.
5
B2
Remote I/O
Communication Module