Ferroli DIVA D C24 Instructions For Use, Installation And Maintenence page 46

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 30
Index
Description
Solar deactivation temperature (b02=1)
Solar deactivation temperature (b02=2)
P19
No effect on adjustment (b02=3)
No effect on adjustment (b02=4)
Solar activation temperature (b02=1)
Solar ignition temperature (b02=2)
P20
No effect on adjustment (b02=3)
No effect on adjustment (b02=4)
Solar standby time (b02=1)
Solar standby time (b02=2)
P21
No effect on adjustment (b02=3)
No effect on adjustment (b02=4)
Notes:
1. Parameters with more than one description vary their function and/or range in relation to the setting of the parameter
given in brackets.
2. Parameters with more than one description are reset to the default value if the parameter given in brackets is mo-
dified.
3. The Maximum Heating Power parameter can also be modified in Test Mode.
Press the Reset button to return to the Service Menu. Press the Reset button for 20 seconds to exit the card Service
Menu, or exiting occurs automatically after 15 minutes.
"In" - Information Menu
Information PAR_INFO is available.
Press the Heating buttons to scroll the list of information in increasing or decreasing order. Press the DHW buttons to
display the value.
Table 4
Index
Description
t01
NTC Heating sensor (°C)
t02
NTC Safety sensor (°C)
t03
NTC DHW sensor (°C)
t04
NTC External sensor (°C)
L05
Actual burner power (%)
F06
Actual Flame resistance (kOhm)
St07
NOT AVAILABLE FOR THIS MODEL
F08
Actual DHW draw-off (L min/10)
PP09
Actual modulating pump speed (%)
Notes:
1. In case of damaged sensor, the card displays hyphens.
Press the Reset button to return to the Service Menu. Press the Reset button for 20 seconds to exit the card Service
Menu or exiting occurs automatically after 15 minutes.
46
Range to use
0÷20°C
0÷20°C
--
--
0÷20°C
0÷20°C
--
--
0-20 seconds
0-20 seconds
--
--
Range
between 05 and 125°C
between 05 and 125°C
between 05 and 125°C
between -30 and 70°C (negative values flash)Without NTC = --
00%=Min., 100%=Max.
00-99 kOhm (-- = burner off)
/
L min/10 over 99 flashing 3 figures
00-100% not working in this model
cod. 3542B920 - Rev 06 - 11/2023
DIVA D C24
DIVA D C24
10
10
10
EN

Advertisement

Table of Contents
loading