Press the reset button again (detail 6 - fig. 1) for 5 seconds to exit the "Sliding Temperature" menu.
If the room temperature is lower than the desired value, it is advisable to set a higher order curve and vice versa. Pro-
ceed by increasing or decreasing in steps of one and check the result in the room.
Adjustments from Remote Timer Control
If the boiler is connected to the Remote Timer Control (optional), the previously described adjustments are
A
managed as described in table 1.
Table 1
Heating temperature adjustment
DHW temperature adjustment
Summer/Winter Switchover
Eco/Comfort selection
Sliding Temperature
EN
90
10
85
80
70
60
50
40
30
20
20
10
fig. 6 - Compensation curves
OFFSET = 20
90
10
9
8
7
85
6
80
5
70
4
60
3
50
2
40
1
30
20
fig. 7 - Example of compensation parallel curve offset
Adjustment can be made from the Remote Timer Control menu and the boiler control
panel.
Adjustment can be made from the Remote Timer Control menu and the boiler control
panel.
Summer mode has priority over a possible Remote Timer Control heating request.
Disabling DHW from the Remote Timer Control menu forces Economy mode. In this
condition, with the off button (detail 7 - fig. 1) on the boiler panel, it cannot be switched
to Comfort mode.
By enabling DHW from the Remote Timer Control menu, the boiler selects Comfort
mode. In this condition, with the off button (detail 7 - fig. 1) on the boiler panel, one of
the two modes (Economy - Comfort) can be selected.
Both the Remote Timer Control and the boiler card manage the Sliding Temperature
adjustment: between the two, the Sliding Temperature of the boiler card has priority.
cod. 3542B920 - Rev 06 - 11/2023
9
8
7
6
5
4
3
2
1
0
-10
-20
OFFSET = 40
90
10
9
8
7
6
5
85
80
70
60
50
40
30
20
4
3
2
1
35