PUMP FAILS TO TURN OFF AFTER ALL FIXTURES ARE CLOSED
Punctured diaphragm.
Discharge line leak.
Defective pressure switch.
Insufficient voltage.
Clogged valves in pump head.
LOW FLOW AND PRESSURE
Air leak at pump intake.
Accumulation of debris inside pump or plumbing.
Worn pump bearing (possibly accompanied by loud noise).
Punctured diaphragm.
Defective motor.
NOISY
Check if the mounting feet are compressed too tightly.
Is the mounting surface flexible? If so, it may be adding noise.
Check for loose head/screws.
If the pump is plumbed with rigid pipe, then it may transmit noise more easily.
Please do follow the instruction manual to install the product. Any action outside what is recommended in this
manual may bring damage to the pump. Any inappropriate installation or operation that causes the pump damage
is not covered by warranty.
CAUTION
page
4
Diaphragm Pump Manual-34 Series
An economical workhorse, the 34 Series are engineered for flexibility. With on-demand switch, up to
2.2GPM and 160PSI, capable of self-priming up to 6 vertical feet, and can run dry, the 34 Series will meet
your special requirements with positive predictable performance. We also offers a variety of easy connect
fittings and filters.

FEATURES

3 chamber diaphragm pump
Continuous duty
Self priming
Run dry capable for normal workloads

APPLICATIONS

Sprayer fixtures (vehicle-mounted sprayers, electric sprayers)
Cleaning machines, humidifier, water purification, medical apparatus
Food beverage filling & liquid transfer
Solar water system
Any other pressurization system

INSTALLATION

Materials
1 diaphragm pump with related accessories
2 (at least) pieces of flexible, reinforced hose piping, with collapsing strength of twice the inlet collapsing
pressure(hose must be minimum 1/2" ID)
4 stainless steel hose clamps and screws
4 screws to fasten the pump to the mounting surface
1 electrical cutoff switch
1 fuse
1 screwdriver
1 strong cutting implement for tubing
(if desired) Teflon tape or sealant

Setup

1. The pump may be mounted in any position. If mounted vertically, the pump head should be in the down
position to avoid leakage into the motor casing in the event of a malfunction.
2. Secure the feet, but do not compress them. Overtightening the securing screws may reduce their ability to
dissipate noise and vibration.
3. Intake hose must be minimum 1/2" (13 mm) ID reinforced hose. Main distribution line from pump outlet should
also be 1/2" (13 mm) ID with branch and individual supply lines to outlets no smaller than 3/8" (10 mm).
Automatic: controlled by pressure switch
Industry standard mounting pattern
Quiet Operation
Ignition protected
page
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 34 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Seaflo 34 Series

  • Page 1 Clogged valves in pump head. 2.2GPM and 160PSI, capable of self-priming up to 6 vertical feet, and can run dry, the 34 Series will meet your special requirements with positive predictable performance. We also offers a variety of easy connect fittings and filters.
  • Page 2 4. Plumb the system using high pressure (2x pump rating), braided, flexible tubing to minimize vibration/noise. Description Quantity 5. Do not apply inlet pressure in excess of 30 psi. In general, try to avoid any inlet pressure completely. Pump Head Assembly 6.

Table of Contents