12. Cleaning, maintenance and trouble shooting

• Store in a dry place, free from frost and damp.
• Clean with a dry cloth. Never clean with water.
• Keep the bare parts of the poles clean. Lubricate regularly with acid-free lubricant for
better contact with the crossbars and to prevent corrosion.
• Also lubricate the pivots regularly.
If the heater produces a loud vibrating sound:
• Stop the heating cycle
• Are all contact surfaces clean and greased?
• Is the crossbar positioned level on the poles?
If this is not the case, follow the instructions below to adjust the crossbar.
Models with horizontal swivel crossbar:
1. Remove dirt, burrs, etc., from the crossbar and poles and lubricate lightly.
2. Place the crossbar on the hinge point and rotate it above the poles.
3. Loosen the socket screws and the bolts on the hinge bushing by about half a turn.
4. Switch on the heater by pressing "START". The crossbar now sets itself. If necessary, a
plastic (dead blow) hammer may be used.
5. When noise reduces, then tighten all bolts and switch off the heater.
WARNING!
• Carrying out the right maintenance and following the instructions is important.
• Contact your supplier if in doubt about the correct functioning of the device.
• Repairs must be carried out by the manufacturer or a specialist approved
by the manufacturer.