3. Specifications
This chapter discusses power requirements, dimensions, and other specifications of the UX302 and
UX402 devices.
Unit Power
Requirement
Temperature
Humidity
External
Dimensions
Weight
Processor
Memory
Magnetic
Stripe card
UX402 is powered by UX302. UX302 device have the following power
requirements:
•
Operating voltage: 9-43V DC
•
Idle Power: <1 W
•
Typical Power: <2 W (CTLS read), 0.5 W (UX102/112)
•
Operating temperature: -30° to 70°C (-22° to 158°F)
•
Storage temperature: -40° to 80°C (-40° to 176°F)
•
Relative humidity: 5% to 90% RH non-condensing
If this device is to be used in any environment where the temperature range
exceeds the product's operating temperature, it is the responsibility of the
integrators to ensure that the ambient environment is controlled in such a way as
to ensure that the product operates within the specified temperature range.
•
Length: 71 mm (2.80 in)
•
Width: 100 mm (3.94 in)
•
Depth: 129 mm (5.08 in)
•
Unit weight: 635g (22.4 oz)
•
ARM Cortex A7 32-bit RISC | 650 MHz
•
512 MB SDRAM (Synchronous Dynamic Random Access Memory)
•
Flash: 2GB
•
Triple track
Installation Guide
UX302 and UX402
19
© VeriFone, Inc. All rights Reserved.