Advertisement

Quick Links

UX302 and UX402
Installation Guide
Verifone Part Number: DOC159-081-EN-A, Revision A
www.verifone.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UX302 and is the answer not in the manual?

Questions and answers

Summary of Contents for VeriFone UX302

  • Page 1 UX302 and UX402 Installation Guide Verifone Part Number: DOC159-081-EN-A, Revision A www.verifone.com...
  • Page 2 The information contained in this document is subject to change without notice. Although Verifone has attempted to ensure the accuracy of the contents of this document, Verifone shall not be liable for technical or editorial errors or omissions contained herein. Verifone and the Verifone logo are registered trademarks of Verifone.
  • Page 3: Table Of Contents

    Connecting UX302 to UX402 ........
  • Page 4 Port Pinouts ............24 © VeriFone, Inc. All rights Reserved.
  • Page 5: Audience

    Installation Guide UX302 and UX402 Preface This guide is the primary source of information for setting up the UX302 and UX402 devices. Audience This guide is intended for the users involved in UX302 and UX402 installations. Organization This guide is organized as follows: •...
  • Page 6: Conventions

    The lightning symbol is used as a For safety, do not string cables or warning when bodily injury might cords across a walkway. occur. © VeriFone, Inc. All rights Reserved.
  • Page 7: Features And Benefits

    • Various connectivity options are integrated into the device. • The LEDs on the UX302 signify device power and status, while the LEDs on the UX402 indicate the progress of contactless card reads. • Buzzer for audio confirmation of card transactions.
  • Page 8: Selecting The Unit Location

    Installation Guide UX302 and UX402 2. Device Setup This chapter describes the setup for the UX302 card reader and UX402, under the following sections: • Selecting the Unit Location • Unpacking the Shipping Carton • Examining the Features of the Unit •...
  • Page 9: Instructions For Unpacking The Shipping Carton

    Grounding cable • UX402 carton • UX402 device • SMA (RF) coaxial cable to connect UX402 to UX302 • RJ45 communications cable to connect UX402 to UX302 • Clamping plate Remove any protective wrap before mounting the unit. Save the shipping carton and packing material for future repacking or moving of the device Do not use a unit that has been tampered with or otherwise damaged.
  • Page 10 Powered USB (Type A) [Host] • Power port 9V DC to 43V DC • LAN with 2 LEDs • RJ45 socket to connect UX402 to UX302 • SMA (RF) coaxial connector to connect UX402 to UX302 © VeriFone, Inc. All rights Reserved.
  • Page 11 Installation Guide UX302 and UX402 The following illustration shows the top view of the UX302. Figure: 3 UX302 Top View Figure: 4 UX402 Antenna Front View Figure: 5 UX402 Antenna Rear View © VeriFone, Inc. All rights Reserved.
  • Page 12: Service Switch

    Please contact your System Mode Verifone representative for details. Cable The connectors on the UX302 rear panel are for power and external device connection. Connections You can connect the UX302 to other devices using any of the following connection types: •...
  • Page 13: Connecting To A Ux102 Or Ux112 Pin Pad

    Figure 11). onnecting Connect one end of the RJ45 connector to the UX302 and the other end to the UX302 to UX402 UX402. Make sure both devices are not more than 0.5 m away from each other. © VeriFone, Inc. All rights Reserved.
  • Page 14: Mounting The Device

    Installation Guide UX302 and UX402 Connect one end of the SMA cable to the UX302 and the other end to the UX402 unit. Figure: 8 Connecting UX302 to a UX402 CTLS Unit Hold the cable and tighten the body. SMA connecter should be tightened by hand only.
  • Page 15: Mounting The Antenna Module

    • Horizontal Mounting position. Align the UX302 stud holes with the holes on the mounting surface. Secure the unit with M5 nuts with a minimum length of 12 mm. Tighten the nuts to the recommended tightening torque of 7.0 kgf.cm (6.1 lbf.in).
  • Page 16 View • Remove the clear protective film from the back of the unit. • Align all the unit's stud bolts with the stud holes of the installation panel. Figure: 12 Mounting a UX402 Device © VeriFone, Inc. All rights Reserved.
  • Page 17: Grounding The Unit

    PIN Pad Modules Remove mounting nuts from the back of the UX302 and the PIN Pad unit (do remove the nut securing the PIN Pad cable retainer). Attach one end of the grounding cable (VPN WIR159-302-02-A) to the UX302 and connect the other end to the system ground termination point.
  • Page 18: Connecting The Power Supply

    Installation Guide UX302 and UX402 Connecting UX302 is not supplied with a power supply, it requires the use of a power supply providing between 9V to 43V DC input. the Power Supply If you have questions about which power supply to use, contact your Verifone representative.
  • Page 19: Unit Power Requirement

    Installation Guide UX302 and UX402 3. Specifications This chapter discusses power requirements, dimensions, and other specifications of the UX302 and UX402 devices. Unit Power UX402 is powered by UX302. UX302 device have the following power requirements: Requirement • Operating voltage: 9-43V DC •...
  • Page 20: Smart Card Reader

    USB Type C (Client/Host) • ETH (LAN) connection with 2 colored LEDs for link state and speed indication • RJ45 socket to connect UX402 to UX302 • SMA (RF) coaxial connector to connect UX402 to UX302 © VeriFone, Inc. All rights Reserved.
  • Page 21: Maintenance And Cleaning

    Installation Guide UX302 and UX402 4. Maintenance and Cleaning The UX302 and UX402 devices have no user-serviceable parts. It can, however, be cleaned. General Care Your device is a product of superior design and craftsmanship and should be treated with care. The following suggestions will help you protect your warranty coverage.
  • Page 22: Service And Support

    Installation Guide UX302 and UX402 5. Service and Support Contact your local Verifone representative or service provider for any problems on your device. For product service and repair information: • USA – Verifone Service and Support Group, 1-800-837-4366, Monday - Friday, 8 A.M. - 8 P.M., Eastern time •...
  • Page 23: Connecting Cables

    Installation Guide UX302 and UX402 One MRA number must be issued for each UX302 and UX402 devices you return to Verifone, even if you are returning several of the same models. Describe the problem(s). Provide the shipping address where the repaired or replacement unit must be returned.
  • Page 24: Pinouts

    Installation Guide UX302 and UX402 6. Pinouts Port Pinouts This section contains port pinout tables for UX302 and UX402. USB A Connector Function Description +5 V 5 V USB Power (500 mA) DATA- USB Host Signal - DATA+ USB Host Signal +...
  • Page 25 Ethernet Port (LAN) Connector Function Description TXD+ Transmit data + TXD- Transmit data - RXD+ Receive data + 75 Ohms AC coupled to GND RXD- Receive data - 75 Ohms AC coupled to GND © VeriFone, Inc. All rights Reserved.
  • Page 26 As commerce experts, we are here for you and your business. With our payment devices, our systems & solutions and our support. Everywhere. Anytime. So that your customers feel enabled, recognized and well taken care of, even beyond their expectations. Verifone. Creating omni-commerce solutions that simply shape powerful customer experiences.

This manual is also suitable for:

Ux402

Table of Contents