To replace the primary filters on
primary filters. Refer to
page 15 .
Pressure tank manometer
The pressure tank manometer shows the pressure in the
pressure tank. The air in the pressure tank cleans the
primary filters. The pressure is around 7 bar/100 PSI
during operation.
Water separator
The water separator removes dirt, oil and water from the
air.
To connect a secondary product
1. Connect the power plug of the secondary product to
an applicable power supply.
2. Make sure that the dust extraction hoses between
the product and the secondary product are
connected with hose clamps and industrial tape.
3. Make sure that the dust extraction hoses are in good
condition and can move freely.
10
To connect the product to a power
source
1. Connect the power plug of the product to a grounded
mains outlet or other power source.
2. Make sure that the mains voltage agrees with the
type plate on the product.
To change the phase sequence
1. Stop the product. Refer to
page 11 .
2. Wait until the product is fully stopped.
3. Disconnect the extension cord from the power plug
on the product.
4. Turn the inverter switch in the power plug on the
product to the opposite position.
5. Connect the power cord and do a check of the
control panel. Refer to
protection and fault power supply on page 10 .
Warning indicator of the motor
protection and fault power supply
The warning indicator of the motor protection comes
on when there is a fault in the power supply. The
motors cannot start when the indicator is on. Disengage
the motor protection to start the motors. Refer to
disengage the motor protection on page 10 .
To disengage the motor protection
1. Change the phases position.
2. Do a check of the warning indicator of the motor
protection. If the indicator is still on, the power supply
is not correct.
3. Do a check of the motor protection switch in the
electrical enclosure.
4. Do a check of the warning indicator of the motor
protection. If the indicator is still on, the power supply
is not correct.
5. Do a check of all phases with a multimeter. Connect
the missing phases.
6. Start the motors. Refer to
page 11 .