VI.

SET-UP

WARNING: VERY HIGH VOLTAGE IS PRESENT ON THE FORK TERMINALS.
REMOVE POWER FROM THE UNIT BEFORE INSTALLING, REMOVING, OR MAKING ADJUSTMENTS

OPERATION

The LP II does not require calibration. When power is applied to the unit, the tines of the fork will begin
vibrating (if the fork is not impeded by contact with material or some other object). The green Power LED will be
illuminated whenever power is applied to the unit. The status of the red Alarm LED is determined by the selected
fail-safe mode and whether or not the fork is vibrating. Refer to Fail-Safe Selection section.

PRODUCT OVERVIEW - STANDARD

Figures 4 and 7 show the electronics of the integral and
remote versions of the LP II respectively. The figures show
the location of the electrical connections, dip switches
SW1, and the Power and Alarm LEDs. This section will
discuss configuration for optimum performance in a given
application. The settings are controlled by SW1 as shown in
Figure 12.
PRODUCT OVERVIEW - ADVANCED ONLY
Figures 4 and 8 show the electronics of the integral and
remote versions of the LP II respectively. The figures show
the location of the electrical connections, dip switches SW5,
two rotary switches SW3 and 4, and the Power and Alarm
LEDs. This section will discuss configuration for optimum
performance in a given application. The settings are
controlled by SW3 through 5 as shown in Figure 13.
BUILD UP DETECTION - ADVANCED ONLY
If the LP II detects that product is beginning to build up on
the forks and may inhibit normal operations of the unit, the
auxiliary relay will drop out and the Power LED will flash. To
avoid false readings, remove the unit, clean material adhered
to the forks and reinstall.
Figure 12: Switch Functions, Standard
Figure 13: Switch Functions, Advanced