Troubleshooting - Musical Fidelity NU-VISTA Series Installation Manual

Hide thumbs Also See for NU-VISTA Series:
Table of Contents

Advertisement

Troubleshooting

Problem
No power.
No sound.
Sound too quiet/loud.
Sound is not precise,
lacking in bass and stereo
image.
Hum.
Pop or click heard in
speakers
when switching on or off
or
changing options.
Distorted sound.
Distorted and loud
sound.
If none of these actions affect a cure, please contact the dealer, or an authorised Musical Fidelity
service agent.
Remember; never open the case of the Nu-Vista Vinyl 2, as this will invalidate the warranty.
Probable Cause
Power plug is not inserted
into socket correctly.
Wrong connections
between input sources
and the unit
Cartridge incorrectly wired.
Wrong MM/MC
cartridge selection.
Cartridge incorrectly wired.
Input connector plugs not
fully pushed in.
Output connector plugs
not fully pushed in.
Turntable not earthed or
needs earthing.
Turntable already
earthed and earthing
further creates hum
loop in system.
Earth loops already in
system
being amplified.
Audio connector plug not
fully pushed in
Cable fault.
Unsuitable Cable
(e .g . cable grounds
not connected).
High gain of Nu-
Vista Vinyl 2,
amplifying normal
circuit transients.
Cartridge and/or tone
arm not aligned properly.
Cartridge fault or worn
needle. Dirt on record.
Line outputs of Nu-Vista
Vinyl 2 plugged into
PHONO amplifier inputs
of following amplifier.
Remedy
Plug in securely into unit's IEC socket.
Check audio input and output lead connections.
Check cartridge wiring.
Use MM setting for MM
cartridges. Use MC setting for
MC cartridges.
Check turntable tracking weight and cartridge
setup. Check plugs are inserted fully and
securely.
Check turntable earthing lead is connected to earthing post.
Disconnect earthing lead from earthing post.
Investigate for earth loops elsewhere in system.
Insert plug securely and check cable is connected at both ends.
N .B . some esoteric cables have internal wiring intentionally
disconnected/ modified. For best results on all inputs AND
outputs, please use good quality screened coax; fully
connected signal-to signal, screen-to-screen.
Not a fault. It is recommended that the volume level on
amplifier is turned down if switching the Nu-Vista Vinyl 2 on or
off; or pressing option switches whilst connected.
Carefully follow turntable instructions to correctly re-align tone
arm and cartridge.
Replace needle or cartridge.
Clean dust and dirt from
record.
Use LINE level inputs only, e.g. an AUX input.
PROBLEMS?
P a g e
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nu-vista vinyl 2

Table of Contents