Atlas Copco GA 110 VSD+ Instruction Book page 107

Table of Contents

Advertisement

Instruction book
The condensate enters the electronic water drain via inlet (1) and accumulates in collector (6). A
capacitive sensor (5) continuously measures the liquid level.
The pilot valve (3) is activated as soon as the collector is filled up to a certain level. Diaphragm
(4) opens outlet (8), discharging the condensate.
When the collector has been emptied, the outlet closes quickly without wasting compressed air.
When the controller registers a malfunction, the red alarm LED on the control panel of the
electronic water drain starts flashing, a warning appears on the display of the regulator and the
electronic drain valve will automatically change to the alarm mode, opening and closing the valve
according to a sequence as shown below . This condition continues until the fault is remedied. If
the fault is not remedied automatically, maintenance is required.
Testing the Electronic water drain
Briefly press the TEST button and check that the valve opens for condensate discharge.
Checking the alarm signal
• Press and hold the test button for at least 1 minute.
• Check that the alarm LED flashes.
9829 3178 63
Drain frequency during alarm condition
Control panel
105

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ga 132 vsd+Ga 160 vsd+

Table of Contents