Download Print this page

Eldat Easywave neo RCJ35 Manual page 3

Flush-mounted receiver 230v motor potential loaded

Advertisement

PROGRAMMING
Measuring the runtime
The runtime of the RCJ35 outputs can be set individually for both directions. This protects the end po-
sition switches of a connected motor and enables the targeted approach of positions when controlled
by a server (e.g. APC01).
Each movement command received is carried out for the currently set runtime. This runtime applies to
all programmed transmitters, even if the transmitters were already programmed before a measurement.
The maximum runtime that can be set is approx. 1.8 hours.
To be able to carry out a runtime measurement, at least one transmitter must be programmed into the
RCJ35. Start the runtime measurement with the roller shutter completely open. Then, using a program-
med transmitter, move the roller shutter to both end positions and give a STOP command as soon as the
roller shutter has reached an end position (regardless of whether the roller shutter has already stopped
independently). The more precisely you send the STOP command when the end positions are reached,
the more precisely positions can be approached later with a server (e.g. APC01).
You can repeat the measuring runs as often as you like as long as the runtime measurement is active.
The last measured runtime for each direction is saved. If the runtime measurement was started with a
transmitter, it must be completed with exactly the same transmitter. Other transmitters are ignored for
the duration of the measurement.
The factory setting (restored after a reset) for the runtime is 90 seconds for both directions.
Operation
Indication
[Press button]
P
3x briefly
LED flashes red
P
1x long
LED P flashes alternately red|green
move to both
LED P flashes alternately red|green
end positions
P
1x long
LED P lights up
2 seconds green
If an attempt is made to start the runtime measurement without at least one transmitter being
programmed, the LED P flickers red for 4 seconds and the receiver switches back to operating
mode.
The runtime measurement can be cancelled by briefly pressing the programming button P. This
discards all currently measured values.
Deleting transmitters
In delete mode, individual transmitters can be specifically deleted from the memory of the RCJ35.
Operation
Indication
[Press button]
P
1x long
LED P flashes quickly red
Tx 1x briefly
LED P lights up
2 seconds red
Reset
Doing a RESET, the receiver will be set back to the factory settings. All programmed transmitters are
deleted and the runtime for both directions is set to 90 seconds again.
Operation
Indication
[Press button]
P 1x long
LED P flashes quickly red
P 1x long
LED P lights up
4 seconds red
Note
start RUNTIME MEASUREMENT
Move the roller shutter to both end po-
sitions using a programmed transmit-
ter. Send a STOP command at both
end positions!
For each direction of travel, the last
movement time between two STOP
commands is measured.
Ends the runtime measurement and
saves the values.
When the LED turns off, the receiver
is ready for operation.
Note
Receiver in delete mode.
Transmitter has been deleted.
Note
Receiver in delete mode.
All transmission codes have been
deleted and the factory settings have
been restored.
Open the roller shutter
completely
(move to the upper
end position and send
STOP)
c
P
3x briefly + 1x long   
d
Close the roller shutter com-
pletely
Send STOP when the lower
end position is reached.
Open the roller shutter completely
Send STOP when the upper
end position is reached.
P
e
1x long Ends the runtime
measurement and saves
the values.
P
1x long
c
d
c
P
d
1x long
start RUNTIME
MEASUREMENT
Tx
P
1x long
3

Advertisement

loading

This manual is also suitable for: