Download Print this page

Eldat Easywave neo RCJ35 Manual page 2

Flush-mounted receiver 230v motor potential loaded

Advertisement

SETTING UP THE RECEIVER
The receiver must be installed and commissioned by a qualified electrician 
in a commercially available flush-mounted installation box.
1. Switch off the power supply.
2. Connect the supply voltage and the tubular
motor to be controlled according to the wiring
diagram. Observe the applicable electrical re-
gulations!
PROGRAMMING
Program transmitters
The RCJ35 only responds to programmed Easywave transmitters. To program a transmitter, set the
RCJ35 to the programming mode for the desired operating mode and then press the transmitter button
to be programmed or, if necessary, a button connected to the T1/T2 button input. Up to 32 transmission
codes can be programmed. If an already programmed transmitter is programmed again, the previous
operation mode is overwritten by the new selection. A button input occupies a memory location as soon
as it is programmed into another than the default operating mode.
Operation
[Press button]
UP/DOWN
2-TB
P
1x briefly
Tx
Transmitter
button
1x briefly
UP/DOWN
2-TB
P
1x briefly
P
1x long
Tx
Transmitter
button
1x briefly
UP/STOP/DOWN
3-TB
P
2x briefly
Tx
Transmitter
button
1x briefly
UP/STOP/DOWN
3-TB
P
2x briefly
P
1x long
Tx
Transmitter
button
1x briefly
SEQUENCE
1-TB
P
3x briefly
Tx
Transmitter
button
1x briefly
RUNTIME
MEASUREMENT
P
3x briefly
P
1x long
EXPLANATION
LED indications
lights up
off
flashes
flashes quickly
2
3. Switch on the power supply again and trans-
fer the coding of the transmitter buttons to the
receiver (see „Program transmitters").
4. Seal the flush-mounted installation box with
the corresponding cover.
Indication
Note
Operating mode UP/DOWN selected
LED P flashes red
LED P lights up
Transmission code is programmed.
2 seconds red
When the LED turns off, the receiver
is ready for operation.
LED P flashes red
Operating mode UP/DOWN
LED P flashes green
Operating mode UP/DOWN + slat adjust-
ment selected
LED P lights up
Transmission code is programmed.
2 seconds green
When the LED turns off, the receiver
is ready for operation.
Operating mode UP/STOP/DOWN selected
LED P flashes red
LED P lights up
Transmission code is programmed.
2 seconds red
When the LED turns off, the receiver
is ready for operation.
LED P flashes red
Operating mode UP/STOP/DOWN
Operating mode UP/STOP/DOWN + slat
LED P flashes green
adjustment selected
LED P lights up
Transmission code is programmed.
2 seconds green
When the LED turns off, the receiver
is ready for operation.
LED P flashes red
Operating mode SEQUENCE selected
LED P lights up
Transmission code is programmed.
2 seconds red
When the LED turns off, the receiver
is ready for operation.
LED P flashes red
Operating mode SEQUENCE selected
LED P flashes alter-
start RUNTIME MEASUREMENT
nately red|green
(see page 3)
Press button
briefly (< 2 s) = Press button for less than 2 seconds
long (> 2 s)
= Press button longer than 2 seconds
with slat adjustment
with slat adjustment
Operation
1-TB = 1-button operation
2-TB = 2-button operation
3-TB = 3-button operation
The cable length for connecting external
buttons must not exceed 3 meters.
Make sure there is no interference with the
wireless connection! Do not mount the de-
vice in a distribution box, in metal casings or
in direct proximity to large metal objects.
Programming structure
Programming level 1
Ready for operation
P <2 s
UP/DOWN
2-TB
P >2 s
UP/DOWN
P <2 s
2-TB with
slat adjustment
UP/STOP/DOWN
3-TB
P >2 s
UP/STOP/DOWN
P <2 s
3-TB with
slat adjustment
SEQUENCE
1-TB
P >2 s
RUNTIME
P <2 s
MEASUREMENT
Ready for operation
P
c
Select operating mode
Send transmission code
Tx
d
A programming process can be cancelled by
briefly pressing the P programming button
several times. Once the LED turns off, the
receiver returned to standby.
Programming level 2

Advertisement

loading

This manual is also suitable for:

Easywave neo rcj35en5001a01