Step
9. Remove electric box assy
a. Remove the fastening screw of wire clamp;
b. Remove the 2 screws of grounding wire;
c. Remove the fastening screw of electric box;
d. Remove the electric box assy.
10. Remove ventilation assy (fresh air)
a. Use a screwdriver to remove the 3 fastening screws
of the ventilation assy (fresh air);
b. Remove the ventilation assy (fresh air).
11. Remove connecting pipe clamp
Remove the connecting pipe clamp by hand to separate
the connecting pipe clamp from the rear case.
Installation and Maintenance
Procedure
Fastening screw
Fastening screw
Ventilation assy
(fresh air)
Connecting
pipe clamp
Screws of
grounding wire
Fastening
screw of
electric box
Wire
Rear
Electric
clamp
case
box