● Setting Angle of Air Flow
Setting vertical angle of air ow
While the unit is on, use the SWING/DIRECT
button on remote control to set the direction
(vertical angle) of airflow. Please refer to the Re
mote Control Manual for details.
NOTE ON LOUVER ANGLES
When using COOL or DRY mode, do not set
louver at too vertical an angle for long periods
of time. This can cause water to condense on
the louver blade, which will drop on your floor or
furnishings.
When using COOL or HEAT mode, setting the
louver at too vertical an angle can reduce the
performance of the unit due to restricted air flow.
Setting horizontal angle of air flow
The horizontal angle of the airflow must be set
manually. Grip the deflector rod (See Fig.B) and
manually adjust it to your preferred direction.
For some units, the horizontal angle of the airflow
can be set by remote control. please refer to the
Remote Control Manual.

Manual Operation (without remote)

CAUTION
The manual button is intended for testing purposes
and emergency operation only. Please do not
use this function unless the remote control is lost
and it is absolutely necessary. To restore regular
operation, use the remote control to activate
the unit. Unit must be turned off before manual
operation.
To operate your unit manually:
1. Open the front panel of the indoor unit.
2. Locate the MANUAL CONTROL button on
the right-hand side of the unit.
3. Press the MANUAL CONTROL button one
time to activate FORCED AUTO mode.
4. Press the MANUAL CONTROL button again
to activate FORCED COOLING mode.
5. Press the MANUAL CONTROL button a third
time to turn the unit off.
6. Close the front panel.
13
NOTE: Do not move louver by hand. This will
cause the louver to become out of sync. If this
occurs, turn off the unit and unplug it for a few
seconds, then restart the unit. This will reset the
louver.
Fig. A
CAUTION
Do not put your fingers in or near the blower and
suction side of the unit. The high-speed fan inside
the unit may cause injury.