4.3 Electrical Connections:
All electrical connections must be made by authorized service personnel in accordance with local and national
standards and directives.
All products must be connected to the residual current device of 30mA.
Use the power socket and an appropriate connector to connect the appliance. Power socket is on the side.
This connection is additional to existing grounding.
Before connection, make sure that rated voltage on the name plate matches the mains voltage. Furthermore,
also the fuse rating should match product specifications.
If power cable is damaged, please obtain a replacement from Öztiryakiler or authorized service.
Electrical ratings are marked on the product's name plate.
4.4. Water Connection:
A 3/4" water inlet hose is provided with the appliance. Use this hose for water connection and check water
tightness on connections and the hose.
When installing the appliance, use the new hose provided. Avoid using old damaged hoses.
Washing performance of the product depends on external conditions such as water inlet temperature,
pressure, hardness and chemicals used (detergent, polisher). To increase the service life and washing
performance of the appliance, supply water should have proper hardness. Otherwise, use a water softening
device.
Caution! Any damage resulting from the use of hard water will not be the manufacturer's or dealer's liability, and voids
the product warranty.
4.5. Limits in Water Connection:
Water inlet temperature: 4-50°C.
Inlet pressure of flowing water: A rinsing pump is needed if pressure is 0-2 bars. A pressure of 2-4 bars is
appropriate. If pressure exceeds 4 bars, adjust the pressure using the pressure regulator.
If these conditions cannot be satisfied, appliance's washing performance would decline.
4.6. Drain Connection:
4.6.1. Models Without a Drain Pump:
In models without a drain pump, waste water is transferred to the drain vent by gravity. Drain hose should run
to the drain vent with a downward slope. Therefore, drain vent height should be max. 100 mm. Never reduce
the diameter of the drain hose.
Allow a adequately long drain hose so that the appliance can safely be moved during servicing. Drain vent
diameter should be Ø42 mm (1 1/4ʺ) and drain should be below the hose outlet level. Make sure that the
hose-drain vent connection is watertight.