Function ......................................................... 6 20 Returns; Control Function; Gemü Conexo - GEM 650TL Operating Instructions Manual

Manually operated diaphragm valve
Table of Contents

Advertisement

4 GEMÜ CONEXO
ator is supplied with compressed air. If this supply is interrup-
ted, the valve closes due to the force of the spring and can no
longer be opened manually.
3.3 Function
The closed position feedback of pneumatic piston and hand-
wheel takes place via flush mountable proximity switches (op-
tional). The valve has CIP/SIP cleaning and sterilizing capabil-
ities.

3.4 Control function

The following control functions are available:
Control function 1: Normally closed (NC)
3.5 Optical position indicator
The product has an optical position indicator as standard. The
optical position indicator indicates the OPEN and CLOSED po-
sitions.
GEMÜ 650 0TL
Valve open*
GEMÜ 650 1TL/650 2TL
Valve open*
* Only if control medium has been applied to the actuator and
the manual actuator has been put in the OPEN position.
GEMÜ 650TL
Valve closed
Valve closed
6 / 42
4 GEMÜ CONEXO
The interaction of valve components that are equipped with
RFID chips and an associated IT infrastructure actively in-
crease process reliability.
Thanks to serialization, every valve and every relevant valve
component such as the body, actuator or diaphragm, and
even automation components, can be clearly traced and read
using the CONEXO pen RFID reader. The CONEXO app, which
can be installed on mobile devices, not only facilitates and im-
proves the "installation qualification" process, but also makes
the maintenance process much more transparent and easier
to document. The app actively guides the maintenance techni-
cian through the maintenance schedule and directly provides
him with all the information assigned to the valve, such as
test reports, testing documentation and maintenance histor-
ies. The CONEXO portal acts as a central element, helping to
collect, manage and process all data.
For further information on GEMÜ CONEXO please visit:
www.gemu-group.com/conexo
5 Correct use
Danger of explosion!
▶ Risk of severe injury or death
Do not use the product in potentially
explosive zones.
Only use the product in potentially ex-
plosive zones confirmed in the declara-
tion of conformity.
Improper use of the product!
▶ Risk of severe injury or death
▶ Manufacturer liability and guarantee will be void.
Only use the product in accordance with the operating
conditions specified in the contract documentation and in
this document.
The product is designed for installation in piping systems and
for controlling a working medium.
1. Use the product in accordance with the technical data.
2. Note the supplement acc. to ATEX
3. Please note the flow direction on the valve body.
DANGER
WARNING
www.gemu-group.com

Advertisement

Table of Contents
loading

Table of Contents