Control pressure:
Filling volume:

7.4 Product conformity

Pressure Equipment Dir-
ective:
Machinery Directive:
Food:
Oxygen:
TA Luft (German Clean
Air Act):
SIL:
www.gemu-group.com
Control function 1
Actuator version
0TL, 0RL, 0LL
1TL, 1RL, 1LL
1HL, 1ML, 1SL
2TL, 2RL, 2LL
2HL, 2ML, 2SL
All pressures are gauge pressures.
MG = diaphragm size
Control function 1
Actuator version
0TL, 0RL, 0LL
1TL, 1RL, 1LL,
1HL, 1ML, 1SL
2TL, 2RL, 2LL,
2HL, 2ML, 2SL
2014/68/EU
2006/42/EC
FDA
Regulation (EC) No. 1935/2004
Regulation (EC) No. 10/2011
Regulation (EC) No. 2023/2006
USP Class VI
CRN
* depending on version and/or operating parameters
BAM compliant, the product is suitable for application with oxygen
(special version code S)
The product complies with the equivalence requirements of section 5.2.6.4 of the German Clean Air
Act (TA Luft / VDI 2440 according to section 3.3.1.3)
Product description:
Device type:
Fail safe function:
HFT (Hardware Fault Tolerance): 0
MTTR (Mean Time To Restora-
tion):
Product description:
Device type:
Fail safe function:
HFT (Hardware Fault Tolerance): 0
MTTR (Mean Time To Restora-
tion):
DN
4 - 15
10 - 20
15 - 25
DN
4 - 15
10 - 20
15 - 25
GEMÜ diaphragm valve 650TL
A
Due to the fail safe function, the diaphragm valve is placed in the
closed position (with control function 1).
24 hours
GEMÜ diaphragm valve 650TLwith GEMÜ 032x pilot solenoid
valve
A
Due to the fail safe function, the diaphragm valve is placed in the
closed position (with control function 1).
24 hours
11 / 42
7 Technical data
MG
Control pressure
8
5.0 - 7.0
10
5.0 - 7.0
5.0 - 8.0
25
4.0 - 7.0
5.0 - 8.0
MG
Filling volume [dm³]
8
0.01
10
0.02
25
0.06
GEMÜ 650TL